    Goulds water pump
    I hooked up a goulds 3/4 hp water jet pump to irrigate my lawn. I attached a rainbow sprinkler to a hose that I attached to the discharge line. Water is flowing well but vacuum gauge reads about 26 hg. Manual says anything over 22 is too much of a vacuum. The manual states the cause of this high vacuum is that the check valve is stuck closed or the suction pipe is buried in the mud. The water is very clear coming out so I don't think it is stuck in mud and the water is coming out fast so I don't see how the check valve could be stuck closed. Also the pressure gauge needle is shaking rapidly between 40 to 50 psi. This is on a sand point well that is only about 13 feet in the ground. When I did the well there was about 4 feet of water up the pipe. I ran the pump today for the first time and in about 10 minutes the pump was already pretty hot to the touch. Any ideas what I can do to fix this or is this normal. Any incite would be much appreciated. Thanks.
    Ochalus's Avatar
    Ochalus Posts: 7, Reputation: 1
    New Member
     
    #2

    May 21, 2014, 12:27 PM
    I was able to speak with goulds pump rep who advised this is normal operation. No need to respond. Thanks though.
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #3

    May 21, 2014, 05:03 PM
    Glad you got it fixed. I'm not familiar with a vacuum measurement on a pump, though I could see it could be useful. The pump getting hot would concern me, but evidently that is not a problem.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

We have lost water to our hose, in the pump house the submersible pump motor trips [ 3 Answers ]

We lost water, so we went to the pump house the submersible pump motor tripped, we clicked the reset button and it builds pressure to about 38 PSI then trips again, so we replaced the motor, no change does same problem, so we replaced the 30/50 pressure switch, same problem exists.

J10s goulds pump [ 0 Answers ]

We have had to replacethe impeller and defuser several times. Our tenant swears that they are not empting the tank. What could be the cause

How to have goulds jet pump turn on sooner [ 1 Answers ]

Have a 1/2 goulds jet pump in my basement how do I set the pump to turn on sooner it turns on at 27psi I want it at 40 psi its shuts off at 50 psi which I like

Does a condenser centrifugal pump suit t work asa chilled water pump [ 0 Answers ]

I have 3 cenreifugal pump which are used for the condenser cooling water recirculation, may I could use it as a chilled water pumps and get another smaller pumps for cooling water recirculation, thank u in advance.

Goulds j10s pressure problem [ 1 Answers ]

I have a goulds 1 hp with J10S and since I opened the impeller casing to clean the insides including the impeller I noticed that after re-assembling everything back it does not generate as much pressure and therefore volume vs. before I opened the casing. Is there something I should particularly...


View more questions Search