    Bryant 340mav trouble codes
    Bryant 340MAV giving trouble code 33. We replaced the filter - shut off the power for 30min to reset the code- worked for about 6 hrs. now it is showing code 33 again. Blower works, but heat won't kick on.
    Irishscarlett's Avatar
    Irishscarlett Posts: 3, Reputation: 1
    New Member
     
    #2

    Feb 1, 2010, 10:01 PM

    Codes given in book:
    13 or 33 - Limit switch lockout
    14 or 34 - Ignition lockout/proving fault
    24 - furnace fuse open
    31 - pressure switch not closed
    12, 21, 22, 23 - call dealer!

    How do you reset these?
    sse's Avatar
    sse Posts: 5, Reputation: 1
    New Member
     
    #3

    Feb 6, 2010, 08:43 AM
    I have exactly the same problem. Did you ever find a solution as to how to reset? Anyone?

    Thank you!
    Irishscarlett's Avatar
    Irishscarlett Posts: 3, Reputation: 1
    New Member
     
    #4

    Feb 6, 2010, 08:57 AM
    Yes, I called out a tech! Basically I overheated my furnace with a filter that hadn't been changed in... oh, say... 6mo! It needed to be reset to clear the code. His fix?? Yeah, best entertaining $80 I ever spent... he tapped "the right spot" with the handle to his screwdriver. Doh! So... moral of the story? Buy yourself the CHEAP filters & make sure they are changed every month... say on the 1st! He also mentioned that my "waffle" type of filter (yeah, more expensive) wasn't nessessary on this high efficiency furnace... just use the cheap ones & don't forget to change them out. Oh, and don't block any intake vents (mine weren't), because that can also sufforcate the furnace. I hope that helps you! I don't know about you, but only when I go camping do I expect to layer up... not in my own house! LOL
    sse's Avatar
    sse Posts: 5, Reputation: 1
    New Member
     
    #5

    Feb 6, 2010, 12:59 PM
    Hi there, thanks so much for the quick response. Do you know where he tapped? I am pretty handy, but am having trouble figuring this one out. Did he tap on a stuck switch? Luckily we've got a gas fireplace and an electric space heater to keep us warm!
    chadv's Avatar
    chadv Posts: 1, Reputation: 1
    New Member
     
    #6

    Feb 25, 2012, 09:04 AM
    I had the same problem with my 340MAV just blowing cold air. (old filter needed to be replaced) Shutting down never helped but this post did help in that it forced me to look harder for the reset switch. There are 2 wires going to the burner and the switch is a tiny button in between them. Take a look at the following manual and it it item number 17. Although, mine had two wires going to either side of that switch and you had to look hard to see it. As soon as I hit that switch it reset and started working within minutes.

    -- > http://www.gogeisel.com/geiselonline/support/Bryant/340MAV_350MAV_355MAV_OM.pdf

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bryant 373LAV trouble codes [ 2 Answers ]

My Bryant 373LAV appears locked out. The trouble code is 3 short and 1 long. The trouble code sticker is missing from the blower door. Can anyone identify the code's meaning?

Bryant heater codes model 588anw036100aaaf [ 2 Answers ]

Unit will not start without disconnecting power then will not shut off at set temp. Replaced thermostat-no help. LED blinks 8x,, PC board looks to have gotten real hot around 2 resistors on left side below a relay. Any ideas what the blink-code means??

Bryant Error Codes [ 1 Answers ]

Trying to find error codes for Bryant Furnace it's 7 years old (can't read the model #) I am getting 4 slow red flashes followed by 3 quick ones. Thanks for any help.

As to the bryant gaspack codes [ 1 Answers ]

The error code said processor detected error in software or hardware. It has a code for flame sensor.

Bryant Gaspack LED codes [ 1 Answers ]

I have a 588ANW048120 gaspac and the code led refers to the IGC error, I can reset the unit by cutting off main power and it comes on and works ofay for awhile then all of a sudden it does the same thing. Sometimes it will work OK for aday or two then again it may go and do it two times in one day....


View more questions Search