    4" pvc to soil stack tee
    I need to replace a bad section of my cast iron main stack with 4" pvc. I am replacing the vertical straight pip section that connects to the sanitary tee that connects to the toilet drain.

    Can the cast iron tee fit into the pvc pipe?
    If not, how do I set this up to so that the pvc pipe connects to the cast iron tee on the main stack?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Apr 21, 2012, 08:21 AM
    Quote Originally Posted by c111998 View Post
    I need to replace a bad section of my cast iron main stack with 4" pvc. I am replacing the vertical straight pip section that connects to the sanitary tee that connects to the toilet drain.

    Can the cast iron tee fit into the pvc pipe?
    If not, how do I set this up to so that the pvc pipe connects to the cast iron tee on the main stack?
    Let me walk you through the process. You will need,
    a 4"raiser clamp ,(see image)
    a ratchet type soil pipe cutter, (see image
    2 4" shielded metal couplings, (see image)
    So the stack doesn't fall you'll have to prop the soil pipe up. (see image)
    Place the raiser clamp 4 or 5 inches under the tee and cut 2 X 4s to prop up the tee after you make your c ut.
    With the upper part secured you may now cut out the bad section.
    Measure between the two cuts and cut the PVC 3/8ths of a inch shorter.
    Take the metal bands,(less the rubbers) and slip them over the cast iron pipe ends, Roll the rubber back and insert the PVC pipe. Snap the rubbers back and tighten the couplings and your job is complete. Good luck, Tom.
    Attached Images
        

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Can you replace a 4 inch cast iron soil stack with 3 inch pvc? [ 3 Answers ]

I recently purchased a home built (I'm guessing) in the early 1900's. I noticed a leak in my basement coming from the old 4 inch cast iron soil stack running from my second floor bathroom to the basement. There is water dripping down the pipe to the basement. Three plumbers have come out to...

Add a PVC wye to a 4" cast iron soil pipe [ 3 Answers ]

I have to add a 2 inch line to an existing underground 4" buried cast iron soil pipe. I can follow the shielded coupling of a PVC wye. My question is, how do you clean up the lumpy cast iron pipe so that the perfectly round and smooth coupling actually makes a sealable joint?

Attaching new 2" drain pipe to existing 3" soil stack - PVC [ 4 Answers ]

All, I am installing an additional sink on the main level of my home. On the lower level, below, there is a main 3" soil stack. I am thinking to use a 3"x2" Y connector to tie 2" drain pipe into this main soil stack. The sink will be vented using AAV (island) Questions: 1. Is there any...

Cast iron soil stack to pvc [ 15 Answers ]

the plumbing in our house is from 1936. We noticed a large stain in the ceiling, tore it out to reveal the cast iron soil stack (runs from the upstairs bathroom turns a corner then runs straight to the basement) and found the leak was around (very bad leak) the lead joint. My husband finally got...

Basement 4" PVC stack [ 1 Answers ]

Hi, I posted a while back about doing a basement bathroom and am about to start the project. I was wondering if there is a rule or code that requires the 4"PVC stack to extend all the way to the joists in the basement before going with a reducing bushing to take off with the vent, OR, can I save...


View more questions Search