Ask Experts Questions for FREE Help !
Ask
    mongo66's Avatar
    mongo66 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jan 2, 2016, 04:28 PM
    Older air ease furnace pilot lights but goes out
    The pilot light will light but when I switch the gas valve to on it goes out. I replaced the thermocouple already. Thanks
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Jan 2, 2016, 05:17 PM
    Make sure that the thermocouple is in the flame. Make sure that you have a good connection where the thermocouple screws into the gas valve. Make sure that you are holding the button down long enough.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Johnson Air Ease Furnace pilot light won't re-light. Fire there but no pilot light [ 0 Answers ]

Air Ease (Johnson) furnace pilot light will not re-light. Flame sensor replaced three years ago. Flame left on for a couple minutes but sensor will not allow pilot light to stay on. Going out now to try new pilot light flame sensor. NEED HEAT!

Furnace, model no. Gdpi075-3, I am getting spark to pilot and pilot lights ,spark con [ 2 Answers ]

Furnace, model no. gdpi075-3, I am getting spark to the pilot, pilot lights, spark continues, but valve does not open for main burner. This is a dual stage gas valve. There is 24 volts at pin 4 on the gas valve, I also measure 0.76 volts at spark control, this wire comes from flame sensor. With all...

Air-ease furnace not lighting [ 5 Answers ]

Hi, I have a air-ease furnace and it will not light the gas, I have replace the ignitor,rollout switch and still nothing. Everything else runs and gas is coming out but now stumped on what to check. I hope somebody has an idea can't afford repairman. Can here clicking but nothing happens and then...

My intertherm furnace pilot lights but furnace won't kick on [ 5 Answers ]

I need some diagnostic help. We have a full propane tank. A new burner plate (last year) and the blower works. We light the pilot but the knob should pop up after one minute thus lighting the furnace. It won't pop up. What part should we replace? The furnace is a 17 year old Intertherm MGH...

Gas furnace has an intermittent pilot, pilot lights, furnace tries to start [ 3 Answers ]

Have a 25 plus year old furnace pilot will start when signal sent furnace tries to start makes noise as it tries over and over but will not start. Thanks