    Aug 8, 2014, 09:52 PM
    Rheem fan motor
    My old fan had 3 wire brown orange and black so the new fan only has white and black so what do you do with the new wires
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Aug 9, 2014, 11:50 AM
    Old motor was probably two speed. New motor single speed. Assuming 120 volts, old motor white was neutral, black was probably high speed, orange low speed.

    If you still have old motor check label. If this is gas furnace and a/c air handler combined, you probably should get two speed motor. High speed to a/c, low speed for heat.

    Otherwise connect white to white, black to black.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Rheem criterion fan motor [ 0 Answers ]

Ive got a Rheem Criterion Gas furance and I have this serious vibration coming from it. I've was thinking to replace the fan motor because I'm thinking the motor has been running this long that possible the shaft could be out of straight by now. I've been told the vibration is possible from the fan...

I need the part #s for my rheem a/c condenser fan motor and fan blade and fan grill [ 1 Answers ]

Hi I need to know the parts #S of my rheem a/c condenser unit for the fan motor and fan blade and fan grill? Model # is ralc-g4zjaz

Rheem fan motor replacement [ 0 Answers ]

My old Rheem ac fan motor had 3 wires Orange (common) brown (fan) and black (terminal) and The replacement motor has 4 wires (black, white, brown, brown-white) how do I wire the new motor?

I have a RBHC Rheem A/C, let me know if I can use a dayton motor for the fan? [ 0 Answers ]

I have a RBHC Rheem A/C, let me know if I can use a dayton motor for the fan?

Hello, I have a Rheem ac unit I just had to replace the fan motor. [ 1 Answers ]

The red wire connecting the condencer to the compaciter burned away from compacitor after workinf good for two days so I twisted it back around it and it worked fine for two or three hours and went back off. I check again and the same wire had melted into another wire. Is this thing possibly wired...


View more questions Search