Ask Experts Questions for FREE Help !
Ask
    Riviello's Avatar
    Riviello Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 8, 2010, 07:07 PM
    York diamond 80 pressure switch
    My York diamond 80 furnace does not start. Its message lights 3 times , so according to the table is the pressure switch. I can not find a diagram of the furnace. Where the switch is located?
    kendallc1979's Avatar
    kendallc1979 Posts: 1, Reputation: 1
    New Member
     
    #2

    Oct 22, 2010, 06:49 PM
    FIRST turn off power and gas switch. Be Safe. I just removed the small hose (hose about 4-6 inches long.)from blower to switch at the blower end of hose, blew into and sucked back. You can hear pressure switch work. Then put hose back on. Worked Great... Hope this helps..
    jlu344's Avatar
    jlu344 Posts: 1, Reputation: 1
    New Member
     
    #3

    Dec 17, 2010, 08:04 PM
    This worked for me as written.. Thanks A lot! I have a diamond 80 gas furnace. About 10 years old..
    Vsp007's Avatar
    Vsp007 Posts: 1, Reputation: 1
    New Member
     
    #4

    Oct 29, 2011, 07:44 PM
    I have the same problem but the hose trick did not help. It just makes a humming sound. Any ideas?
    Joloscho's Avatar
    Joloscho Posts: 1, Reputation: 1
    New Member
     
    #5

    Nov 3, 2012, 06:41 AM
    We had a technician come out a couple of years ago for this problem and last year when the same thing occurred removing the tube and inserting paper clip to clean worked... Not this time!! The hint to blow into and suck out on the pressure switch was the key. It extended the time it stayed lit initially but still blew back out but I knew we were onto something. Did it a few more times blowing in for 10 seconds and sucking out for as long as I could. IT WORKED!! Thanks for the suggestion! You just saved us a weekend service call! Woo hoo!

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

York diamond 90 blower won't shut off. Switch to cool and reprogramed thermostat. [ 1 Answers ]

York diamond 90. Blower won't shut off. Switch to cool and reprogramed thermostat. Outside unit runs and cools OK but only way to stop blower is to turn off power to furnace.

York residential furnace pressure switch problem code stuck switch [ 1 Answers ]

I have a york furnace P2MD12H06401A after 1 hour it shuts down and gives a 2 flash error for a stuck pressure switch. The switch is new can it be wired wrong? The old one had 2 white wires piggy back and 1 blue wire. The new switch has 3 separate terminals

York furnace pressure switch stuck open [ 0 Answers ]

I have a york gas furnace. Condensation is leaking out of the exhaust motor. I removed the motor and everything seemed to be fine but when I put it back in and try to start the furnace, the red light flashes 3 times indicating pressure switch stuck open. What do I do now? I'm lost.

Where to find an aux spill switch for york diamond 80 furnace [ 36 Answers ]

I have an error code that says the aux spill swich is open, But I think it is just going bad because it works sometimes and may be getting ready to go bad. Where to find an aux spill switch for york diamond 80 furnace?

York Furnances Pressure Switch [ 1 Answers ]

The heat shuts off and have to reset. According to the Manual it seems the pressure switch is locked. Every 15 minutes have to rest it to come on. Can not locate a service to come out to fix it today, Sunday. Have an infant. Need ti try to fix myself. How to replace the pressure switch?


View more questions Search