    ABS pipe to bronze / brass fitting in sgower pan
    I have a basement fiberglass shower unit probably installed in the mid 1970's. The drain pipe is 2" I.D. ABS which extends up into a 3" I.D. bronze / brass fitting in the pan of the shower. The ABS pipe ends flush with the fitting in the pan. The approximate 1/4" gap between these had been packed with oakum, with no other apparent sealant. The drain now leaks. I have some concern about minor flexing of the shower floor causing movement between the ABS and bronze / brass. What is the best way to fix this seal?
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    May 5, 2010, 06:12 PM

    I know these drains with fat rubber washer that fits around ABS pipe and slides into the opening in brass drain. Then you put over it wedged plastic washer and pack it into the rubber washer.

    I personally don't think oakum should have been used to seal the drain. Plastic pipe is flexible and will get loose from oakum grip.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Removing glued ABS fitting to ABS piping [ 5 Answers ]

I glued an ABS toilet flange to ab ABS pipe roughing. The fitting did not go down all the way and is 1/2" proud of the tile flooring. I now want to remove the fitting and replace with a new fitting. How do I do it without damaging the receiving pipe. Pipe is in concrete floor. Thanks, Bob

How can I remove a Brass/Copper fitting on a cast iron drain pipe [ 1 Answers ]

After removing a copper drain pipe there is a fitting on the cast iron drain pipe where the copper pipe was sweated to. I can see threads and I heated it with a torch but it is very stubborn and does not want to move. How can I remove this more heat? Or should I look for a copper connector with...

How to repair a leak at a pvc and brass nut fitting [ 2 Answers ]

Up in the basement ceiling, a pvc pipe runs vertical up into what appears to be a brass nut type connection. The pvc has water running down it onto the floor. Looks like there should be some kind of seal around the pvc to prevent this from happening. The pvc end is terminated and free floating up...

Shower stem broke off in brass fitting [ 2 Answers ]

How do I remove the remnants of the shower stem from the brass fitting? The metal was fatigued and most of the thread remains inside the brass fitting. Any suggestions?

Shower arm leaks at brass fitting [ 3 Answers ]

I have tried teflon tape and joint compound on the new shower arm I installed and there is still a small leak. What options do I have to correct this problem? Can I epoxy the joint, can it be soldered? Thanks!


View more questions Search