    In a 160 ft. deep well with a submersible pump, pressure has gone from 60 to 45 psi
    Water pressure began to degrade about 2 week ago the pump continued to run with pressure switch at 60PSI, reduced pressure switch to 55 ans it was OK, after 1 week pump could not achieve 55PSI. I dropped the pressure to 50PSI. It continues to degrade. Does this sound like a bad pump?
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Apr 17, 2010, 06:21 AM

    Suggest trying simple and least expensive things first.

    Remove pressure switch and insure that port is clear and clean. Could be a restriction causing inaccurate readings.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Apr 17, 2010, 07:37 AM

    This could also be the impeller going bad. Any dark particles in the water? Remove a aerator and check then screen. Good luck, Tom
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #4

    Apr 17, 2010, 09:33 AM

    It does sound like a bad pump. Could be your gauge is not reading right. Make sure your pressure gauge is good. It such read about the same pressure you get with a tire gauge at the top of the pressure tank. But, that's a stretch. Even if you had restrictions in pipes, that would more affect volume than pressure. I would do as HK suggested, which is to check the little pipe leading to the switch. As he pointed out, it's a cheap fix, but don't pin too many hopes on it.
    howard424's Avatar
    howard424 Posts: 2, Reputation: 1
    New Member
     
    #5

    Apr 23, 2010, 06:43 AM

    Thanks for the advice. It turnrd out to be 2 holes in the galvanized drop pipe
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Apr 23, 2010, 06:46 AM
    Quote Originally Posted by howard424 View Post
    Thanks for the advice. It turnrd out to be 2 holes in the galvanized drop pipe
    We thank you for the update. Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Low pressure from submersible well pump [ 10 Answers ]

I'll summarize what my situation is and what I've done so far. Pressure tank doesn't fill with water Pressure tank air pressure is 28 PSI Tried installing brand new pressure switch and water pressure gauge Water pressure gauge rose to 26 PSI when I turned the pump breaker back on It stays at...

Can't get pressure over 25 psi in my pressure tank [ 4 Answers ]

Hi, For some reason I can't get the gauge for my water tank to go over 25 psi. The problem started about a month ago. We have three bathrooms (2 upstairs one downstairs.) The water pressure use to be great, two people could shower in the two upstairs bathrooms at the same time and still have great...

Submersible pump is working but we can't get pressure to build to the normal 76psi [ 0 Answers ]

We have a well that has been fine for 10 years. The pump that was in there was a 25gallon per minute. We originally installed a pump and it failed right away and was sent back to the manufacturer and it turned out an impeller was installed backwards. They warranty'd it and sent it back to us. ...

Craftsman 2500 psi pressure washer with honda GVC 160 motor [ 1 Answers ]

Will not start. Used it all summer and went to add Stabil and get it ready for winter storage and I cannot get it started. Fuel is on, has gas, replaced spark plug, checked air fillter, and used choke.

Well pump does not hit 50 psi [ 14 Answers ]

Hello everyone- I have a 2" 3 year old well pipe that was never used. I have finally hooked up a 1hp above ground pump to it and it pumps water great. I have a 30 gallon bladder tank and a water softner hooked up to it as well. Question: Pump came set at 30-50 psi in and out so I filled...


View more questions Search