    Cast Iron main stack
    I have a 50 year old house, and the drain lines are 1-1/2" galvanized steel with cast iron elbows and tees. All drain lines run to a cast iron main stack. I need to replace one of the 1-1/2" galvanized steel pipes that enters a 3" leg of a "Y" that looks like a sanitary tee in the main stack. The old 1-1/2" steel pipe was shoved into the 3" opening in the tee and the space around it was filled with lead (I guess to hold it in place and seal it). I thought it was going to be a simple job to replace the steel pipe with ABS, by just butting a 4" diameter ABS pipe top the cast iron "Y" and connecting it with a Fernco coupler containing a SS sleeve, but when I look into the "Y", I see the ID is reduced to about 2" right before it turns downward. I'm worried that if I just connect the ABS pipe directly to the end of the cast iron collar, the ID reduction will form a small lip inside that will catch debris and have the potential to clog. The old steel pipe was inserted all the way up to the reduction point in the " right before it turns downward. I'm worried that if I just connect the ABS pipe directly to the end of the cast iron collar, the ID reduction will form a small lip inside that will catch debris and have the potential to clog. The old steel pipe was inserted all the way up to the reduction point in the ", which probably helped the flow, but I wasn't planning on inserting the the ABS inside the cast iron because I don't think that is the proper way to connect the two types of pipes. What do I do in this situation? Do I just connect the large ABS to the CI with the Fercon connector as planned and not worry about the little lip that sits inside the ", which probably helped the flow, but I wasn't planning on inserting the teh ABS inside the cast iron because I don't think that is the proper way to connect the two types of pipes. What do I do in this situation? Do I just connect the large ABS to the CI with the Fercon connector as planned and not worry about the little lip that sits inside the " at the point it enters the main stack?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Dec 14, 2009, 09:33 AM
    I hope you didn't removed the lead and oakum seal. If it's still in place cut the 1 1/2" galvanized pipe off a few inches from the joint. now purchase a 1 1/2" Fernco Metal Shielded Coupling,(see image) and connect your plastic pipe to that. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Outside cast iron stack in PA Want to replace with PVC [ 6 Answers ]

I just bought a house and it was build in the 1920s. The drainage stack is outside the house and it is starting to leak. I am trying to decide if I should just patch the leaks or replace it with PVC. I am not even sure if that would work. Any suggestions as to where I should start? Thanks

Cast iron to pvc transition for main vent stack [ 4 Answers ]

Hello to all. I am adding a 2nd story to my home. I have a 4" cast iron vent that y's off to pick up a galvanized 2" pipe for the bathroom below. I have a 2 part question. (A) The vent runs horizontally at a 90 for about 6 feet, then goes up through the roof. I would like to cut this out,...

Cast Iron Vent Stack [ 2 Answers ]

I have just purchased a 1950's rental property with a cast iron vent stack. The insurance co. wants me to replace it as they are prone to leaking in older homes. The job seems fairly straight forward, but do you have to replace the elbow/cleanout at the bottom that is cemented into the basement...

Crack in Cast Iron Main soil stack [ 3 Answers ]

:confused: I just moved into a Bi-level house approx. 40-50 years old. It has a Cast Iron Main soil stack (main vertical sewer line). On the lower level I noticed that it has a crack that is approx 5"-6" long about 1/4" thick. Now I bought a new pluming book because of some other repairs I had...

Cast iron vent stack [ 7 Answers ]

I'm installiing a new basement bathroom and when running a vent stack I would like to tap into the existing cast iron with PVC using a saddle on the cast. My question is what method is used to cut a hole in the cast iron, where I wish to place the saddle and connect the PVC.


View more questions Search