    Installing a RTH7500 Honeywell Theromstate
    I currently have a Honeywell T874R 1053 Thermostat with a Q674L 1140 base. I have eight wires coming out of the wall. They are connected to: T, W, G, R, O, Y, B, X2. There is a jumper wire running from W to X2.
    None of the help tutorials that Honeywell has, lets you elect eight wires coming from the wall. I am using the owner's manual and using the diagram for Alternate wiring (for heat pumps only. I have figured out that I should do the following:
    Green G to G
    Red R to R
    Cream W to AUX
    Blue B to C
    Black X2 to E
    Orange O to O/B
    Yellow Y to Y
    That leaves my T wire (cream colored) with nothing to connect to it.

    I read that the T wire is for the Thermister which new thermostats do not use any more and that I should tape this wire off and not use it.

    I do not want to actually do this without an experts opinion. Please advise if this is the correct wiring diagram and if it is okay to tape off the T wire. I have a Trane Multi Stage Heat pump. If taping off the wire is what I should do what is the safest way?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jun 29, 2008, 10:22 AM
    I read that the T wire is for the Thermister which new thermostats do not use any more and that I should tape this wire off and not use it.

    It is of no value today tape it off.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Installing Honeywell RTH7000; where does the X1 go? [ 7 Answers ]

Ok here are all the details. I started with a White-Rodgers Thermostat Type 1F58W-72 and bought a Hunter Set & Save Programmable Thermostat Model 44155C. I took the old one off and labeled all the wires for the new one according to the instruction. It all went well until I realized I had one...

Installing Honeywell RTH6300B from an older 7 wire Honeywell. PROBLEMS [ 4 Answers ]

Hello everyone, I am new here. I found this site which trying to troubleshoot my problem. Any assistance would be GREATLY appreciated. Basically I have an older honeywell programmable thermostat with 7 wires attached. They are as follows... C - Black wire L - Blue wire R- Red wire W2 - brown...

Installing Honeywell RTH7400 [ 1 Answers ]

I am replacing my old thermostat with a new Honeywell RTH7400. Here are the wire terminals from my old one: G Y T R O W B X2

Replacing Honeywell T8411R with Honeywell RTH7500 - wiring problems [ 1 Answers ]

I need help getting my new, programmable thermostat to work. I currently have a dual-stage Heat Pump and A/C unit that works fine. The current thermostat is the Honeywell T8411R. I don't know the number for the subbase, but it's the one that came with the thermostat. The current (operational)...

Installing Honeywell RTH 230B [ 2 Answers ]

I know there have been multiple posts regarding this stat. I've collected them and have them as reference. I was hoping to do this right the first time rather than have to troubleshoot. The RTH230B is replacing an older Honeywell mercury stat that has 4 wires: W1-white G- green Rh-red...


View more questions Search