Ask Experts Questions for FREE Help !
Ask
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #21

    Jun 24, 2009, 06:57 PM

    Replacing foot valve will not increase pressure, it will only hold pressure steady while pump is off and all fixtures are closed. The reason I say jet assemblys can be a pain, is because they have jets in them that can clogg, or wear out(not often) and when this happens, its hard to tell for sure if it's a pump problem or a jet problem. Jet assemblys must be sized exactly to pump, so if you replace the pump, you have to replace the jet assembly, unless you get the same spec pump that you had, and then if it doesn't work you have to pull jet assembly anyway and fix or replace it. I may be talking a little out my arse, because I've only worked on these things a few times, but I had a fight with them every time. Hope someone else can give you some better advice. If not, I would look into replacing the whole works.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #22

    Jun 24, 2009, 07:54 PM
    If you think a foot valve's at fault you can install a check valve on the suction line that's on the surface. Let me know what you think, Tom
    fhgguy's Avatar
    fhgguy Posts: 12, Reputation: 1
    New Member
     
    #23

    Jun 25, 2009, 06:34 AM

    I'm assuming that would be installed before the pump or can it be installed after
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #24

    Jun 25, 2009, 06:46 AM
    Quote Originally Posted by fhgguy View Post
    I'm assuming that would be installed before the pump or can it be installed after
    As I stated, The check valve must be installed ahead of the pump on the suction line(see image). This will replace a open foot valve. Good luck, Tom
    Attached Images
     
    fhgguy's Avatar
    fhgguy Posts: 12, Reputation: 1
    New Member
     
    #25

    Jun 25, 2009, 06:53 AM

    Thanks Tom, the picture was great

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

New Pressure tank won't fill up [ 12 Answers ]

Installed a new 35 Gallon Precharged Pressure tank. Filled the first couple of times with water. Now it won't fill. It's empty. Water not getting into pressure tank. Never had a problem doing this before. Any ideas?

Tank won't fill [ 2 Answers ]

I serviced the flowmaster, connected everything back up, opened the fill valve and the tank started to fill but locked with only an inch of water. I disconnected the line to the tank and turned the water on... no water coming out at all. What's up??

Tank doesn't fill consistently [ 1 Answers ]

I have a newer toilet (5 years) and it doesn't refill consistently. I have tried WD 40 on the mechanism and it worked for a while but I am wondering if there is a better fix since it is doing it again. It is a nuisance to have to wiggle the mechanism to get the water to refill. Thanks...

Toilet tank doesn't fill up all the way [ 1 Answers ]

Toilet tank does not fill up to it's capacity, which does not flush all the waste down. Have to flush two and three times before it's gone. Please help, I'm wasting gals. Of water all day every day


View more questions Search