Mar 14, 2008, 09:30 AM
|
|
Insufficient Water in Dishwasher
I have a Whirlpool Dishwasher Model DU7800XS1 (vintage 1990?). Parts are still available.
In the fill cycle, the water flows very slowly, and barely covers the floor of the tub.
Sometimes there is no water at all, and I have to restart the wash cycle a few times.
It has gotten gradually worse over time.
Is there a filter or something that could be clogged? If so any ideas where it would be located?
Thanks...
PS: I prefer not to replace the dishwasher as it is a match to all my other kitchen appliances.
|
|
 |
Ultra Member
|
|
Mar 14, 2008, 09:57 AM
|
|
Check at the water valve. Shut water off to the unit and disconnect the supply line. There is a screen in there that catches setiment. Remove it and clean it. This should solve your problwm
|
|
 |
Senior Member
|
|
Mar 14, 2008, 06:49 PM
|
|
Esquire1
Thanks for the info. I hope that's all it is.
Before I take it apart, my supply line is copper, and is connected to the valve with a compression fitting (I think). Could there still be a sediment filter in a copper line?
|
|
 |
New Member
|
|
Mar 15, 2008, 07:24 AM
|
|
Do you have hard water? You may have calcium build up, which is what happened to us. You will have to removed as much as you can manually, then run an empty cycle. When there is water in the tub, put some vinegar in the bottom. About a cup or two. Repeat this daily for about two weeks and then once every three to four weeks for upkeep. Hope this helps!
|
|
 |
Senior Member
|
|
Mar 15, 2008, 08:45 AM
|
|
Thanks for the suggestions all. We DO have hard water. I'll try it!
|
|
 |
Senior Member
|
|
Mar 18, 2008, 06:36 AM
|
|
For anyone interested, the problem turned out to be a clogged sediment screen INSIDE the electric water fill valve coming off the supply line.
Not something meant to disassembled, but I did. The screen was press-fit, so I had to soak the whole valve body in vinegar for 2 hours to loosen it up. Problem solved.
I will be adding an in-line sediment filter to the supply line soon to prevent another occurrence.
Thanks again everyone who contributed.
|
|
 |
Home Repair & Remodeling Expert
|
|
Mar 18, 2008, 08:34 AM
|
|
You might want to add that filter further up stream so it will include your sink faucet. Your dishwasher uses only hot water and hot water heaters need occasional draining/flushing to get rid of crud. Attach a hose to the boiler drain at the bottom of the heater and then open the valve by twisting counterclockwise, drain hose needs to go to a drain area some where. Allow the water to drain for about 5 minutes, do this twice per year without shutting off the main water supply. I think that your new inline filter will be pretty clean 24/7 from now on.
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Insufficient dryer heat
[ 2 Answers ]
Hi, everybody = been moving house and home and simply have not had time to visit with you! Which brings me to my need for help: I have a Frigidaire stacked washer and dryer. In the moving, the hinge on the dryer door got bent but my husband straightened it out. Now, however, the dryer needs...
Insufficient AC air return
[ 1 Answers ]
Last year I had a fly by night guy install a/c in my home and now I am suffering for it. The ducts are a complete mess, but I cannot afford to have it professionally repaired right now. The AC unit is a 10 S.E.E.R. unit rated at 22,500 BTUH. My home is an old two-story house. There is a trunk...
Writing a Check w/Insufficient Balance to Cover It
[ 6 Answers ]
Hi,
Isn't it a crime to write a check out to someone well knowing that you don't have the money in the bank to cover it? As I heard it from a colleague, this would be considered a crime, and a big one in Maryland (where I live). Is that true?
I've had three instances with the same person...
Boiler Hot Water Insufficient
[ 1 Answers ]
I have a 6 zone hot water / forced air hybrid heating system. Most of the actual baseboard system is 1958/1980, but works fine. In 2000 I put in a new boiler, AC, and a forced air furnace that gets its heat from hot water flowing through it from the boiler (in addition to the zones). I also have...
Insufficient heat being produced by gas furnace
[ 4 Answers ]
I have a gas furnace, located in the attic, and very warm air blows from a few vents in the ceiling and coolish air comes from other vents in the ceiling. I do not know what could be causing this problem. Please help.
Judd
View more questions
Search
|