    Studor Mini-Vent
    I recently had my kitchen remodeled and the plumber installed a Studor Mini-Vent under the sink. Due to space limitations, he installed it sideways and didn't glue the PVC pipes together so it's easily removed. Is this a proper installation? I am pretty sure this (either the vent or the break in the pipes) is the source of a septic odor that frequently comes from under the sink (usually at night), but my contractor says it's fine, and of course, he's never around when the odor is... :confused:
    Flying Blue Eagle's Avatar
    Flying Blue Eagle Posts: 2,056, Reputation: 225
    Ultra Member
     
    #2

    Oct 8, 2007, 10:53 PM
    NO it is not installed right, it should be stright up ,not setting sideways . It should also be installed before the drain trap . Can he get under the house to install the vent just under floor??
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Oct 9, 2007, 06:52 AM
    Blue Eagle is correct when he said the Studor Vent should be installed in a upright position, however he was mistaken about the location. A vent,(any vent) is placed behind/downstream from a trap. Think about it! You already have a opening to outside air from the drain itself. Adding another such opening,(Studor Vent) is usless. To install a Studor Vent in this location would make the trap into a illegal "S" trap. Sorry Eagle. Tom
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #4

    Oct 9, 2007, 08:16 AM
    Sorry Tom but I need to spread some around. Tom is 100% correct with the install of the AAV. The AAV requires gravity to help close the venting system and that won't happen when you mount it sideways.
    Flying Blue Eagle's Avatar
    Flying Blue Eagle Posts: 2,056, Reputation: 225
    Ultra Member
     
    #5

    Oct 9, 2007, 11:29 PM
    Sorry tom::: i just read my commentand i saw it right off, (should be installed before draintrap)
    sewnsurg's Avatar
    sewnsurg Posts: 1, Reputation: 1
    New Member
     
    #6

    Jun 26, 2012, 07:44 AM
    I have a Studor mini vent that seems to be properly installed. Starting 6 months after it was installed we have frequent sewer odor under the sink where it is installed. Is the vent defective? Isn't it supposed to prevent the odor, not cause it?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Using "Studor" mini vent in bathroom wall [ 1 Answers ]

I am completely renovating a bathroom in a 1973 mobile home. There is no vent stack from any of the toilet, tub or lav fixtures. I plan to install the "Studor" vent in the wall. Can I use one vent for two fixtures or does each fixture need it's own vent?

Venting sewage ejector w/ a studor vent [ 5 Answers ]

Hello, my home builder put drain pipes for tub, toilet and lavatory in basement floor; I'de like to know if venting my sewage ejector w/ a studor vent is up to plumbing code and if it will work for a full bath or must I dry vent it to the supplied vent in basement. Also, will venting the lavatory...

Studor Vent [ 1 Answers ]

I recently got a new roof (flat) after Hurricane Wilma. My bathroom vent pipe had blown out through the roof and the roofers stupidly tarred over the drain. Not wanting to open up the roof, the contracted plumber said that a studor vent could be used instead of opening up the hole on the roof. Even...

Studor Vent Failing? [ 3 Answers ]

We have a Studor Terminal in an inside hallway closet in our home. Occasionally, when you walk by you can smell the sewer gases, the nice rotten egg smell of hydrogen sulfide. I thought these were a one way air vent system and prevented this sort of thing? Is it not functioning properly?...

Studor vent with tow lavs [ 1 Answers ]

I have a 6 foot lav in my new addition. The bath is on the 2nd floor and there is no way to run the drain into the wall because of the joist below the wall. I am going through the floor into the 1st floor joist space with both lav drains. My question is -Can I use one studor vent for both lavs? I...


View more questions Search