    Tying into waste line under slab
    Hello I'm tying a 3 inch horizonal ABS into an existing 3 inch horizonal ABS line at a 90 degree angle under a 4 inch slab.the main line will not move,is there a special y fitting to make the connection. Also have a venting question which would be easier with a picture how do I attach the jpg.Thanks
    tickle's Avatar
    tickle Posts: 23,796, Reputation: 2674
    Expert
     
    #2

    Aug 4, 2007, 02:38 PM
    I hope someone knows what all this means. Sometimes if put in simple plumbing language some of us can help if not a plumbing specialist. So... you will have to wait for a specialist.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Aug 4, 2007, 03:26 PM
    Quote Originally Posted by jh10863
    hello I'm tying a 3 inch horizonal ABS into an existing 3 inch horizonal ABS line at a 90 degree angle under a 4 inch slab.the main line will not move,is there a special y fitting to make the connection. Also have a venting question which would be easier with a picture how do i attach the jpg.Thanks
    You will cut a 3" ABS combination wye and 1/8th bend, (see image), into the main. Cut, prime and glue a short piece of ABS pipe into the hub of the combo. Lay the combo on the main where you wish to take off and mark the length of the fitting from base of hub to end of the glued in pipe. Add 1/4" to the cut to accommodate the Fernco Shielded Coupling,(see image) you will use to make the male to male connection. Be sure to put a level on the branch of the combo and give it a 1/'8th of a bubble slope back to the main.
    To attach a image, scam the image to disc on your computer and run down the page to "manage attachments" and pull it right out of your disc. You have a 293 KB and a 750 Pixel limit on attachments on this site.
    Good luck, Tom
    jh10863's Avatar
    jh10863 Posts: 16, Reputation: 1
    New Member
     
    #4

    Aug 4, 2007, 04:20 PM
    Tying into waste pipe under slab
    Thanks Tom,that's exactly what I needed to know,the guys at the big home store said there was no part to do it with without cutting out half the foundation.
    Next question,where is the best place to vent.the toilet is 5.5 ft from the new tie in and the vent is 3 ft from there the flow is from the old toilet toward the new connection. Also there will be a shower drain between the vent and new fitting.the tubin the pic I was planning on tying into the where the old toilet was and vent between the drain and connection.if that is sufficient that isName:  bath.JPG
Views: 2214
Size:  17.1 KB
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #5

    Aug 5, 2007, 06:44 AM
    Can you draw in the lavatory so I can see where that vent will be? Regards, Tom
    jh10863's Avatar
    jh10863 Posts: 16, Reputation: 1
    New Member
     
    #6

    Aug 5, 2007, 07:32 AM
    Originally there was a tub with drain and water through the slab where the lavatory is now.I don't know how or even if there was a vent there, when I put the lavatory in, the water drained slow so I put on an aav vent.There are only 2 vents,behind the old toilet,my reference is off a little on the diagram where the tub will be(the original lavatory) and the one next to the shower(another lavatory,go figure!)through the attic.From lavatory drain to vent is about 7 ftName:  bath.JPG
Views: 3062
Size:  22.0 KB

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Options for Dishwasher Waste line [ 1 Answers ]

In the past, I have always hooked up the dishwasher waste line to a sink drain waste "T" or to a garbage disposal "T". Is there an approved way to connect it directly to the 2" drain line that the sink is connected to? Or should I stick with what I have been doing. In the current situation,...

Installing Waste Pipe in a Concrete Slab [ 4 Answers ]

I am extending my shed and adding an outside Bathroom, with a toilet, shower and basin. The flooe will be poured concrete. My questions are 1. Do I need to cover the Pipe before I pour the concrete 2. What drop / sloop needs to be in the waste pipe 3. How far should the waste pipes be below the...

Toilet waste line freeze-up? [ 1 Answers ]

My toilet has not been giving me any problems before now. Night before last, the temperature got below freezing. When I went to bed in the evening, it flushed fine. The next morning, the line was blocked almost completely. When I would flush the toilet, the bowl would fill with water, then...