    Venting a basement bathroom
    Hi we are putting in a basement bathroom, and I was wondering about the venting. THe basement bathroom will be directly below the upstairs bathroom . Do I just hook my basement venting into the line that runs from the upstairs or do I rum a whole new pipe through the roof? And where should I install venting in the line ( before the toilet after the toilet or the sink or what?) Any advice would be appreciated towards the plans Thanks
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    May 14, 2007, 04:57 AM
    Most bathroom groups are roughed in like this.
    Toilet connects to sewer main or the stack vent. Lavatory connects to toilet drain and runs a vent off the top the stubout tee out the roof or revents back into a dry vent in the attic.. The toilet wet vents through the lavatory vent and the tub/shower connects to the lavatory drain and is wet vented by it. This is a normal rough in and is acceptable both by local and state codes and also The Standard Plumbing Code Book in 90 percent of the country. Check your local codes.to make sure you're not in the excluded 10 percent.
    The vent off the lavatory may be run out the roof or revented back into a dry vent in the attic or if you're reventing back into a fixtures dry vent you must make your connection at least 6 inches over that fixtures flood rim.
    Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Basement Bathroom Venting [ 1 Answers ]

My question is about venting my basement bathroom group. The builder roughed in for a bathroom and it seems that the 2 inch pipe behind the toilet hole is the vent pipe. Can I simply connect this to the capped off 2 inch pipe the builder left with the label "air vent" written on it and would this...

Bathroom in basement venting question [ 1 Answers ]

Hi, I know this has been asked before but I am still a little confused. We are going to instal a bathroom group in a basement. We are too far away from the main line and will need to vent the group but can't access any existing vents. My question is 1. Does the toilet need to be vented in...

Basement Bathroom Venting [ 2 Answers ]

I had my rough in inspection yesterday, and everything looked good except my venting for my sinks. I am installing a bathroom lav and a wetbar sink, running into a 2" wet vent that already has a tub/shower on it. Since the distance to the furthest sink is just under 5' from the wet vent I thought...

Venting a basement bathroom [ 7 Answers ]

I have a rough in for a full bath in my basement. House was built in 2000 in Pa. Two story colonial. I can locate two vents from the 1st floor bath. One 2" vent right of the WC drain and one 1.5" off the shower on the first floor. There is a 2nd floor bath over the first. I can hear the 2nd...

Venting basement bathroom [ 5 Answers ]

Hi all, First time here. I am finishing my basement in Milwaukee. The washer dumps into a sink which has a 2" line that y's into a 4" drain that is stubbed up from the slab. This is not the main stack. The 4" ties to the main 4" about 12' away under the slab. The 4" stub rises from the...


View more questions Search