Ask Experts Questions for FREE Help !
Ask
    dougupnorth's Avatar
    dougupnorth Posts: 2, Reputation: 1
    New Member
     
    #1

    Jun 2, 2018, 01:51 AM
    No water coming out of a new corvina model 9090.501
    I have installed a new american standard Corvina pressure balancing bath and shower set. Turned it on but no water coming out. Water up to the control.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Jun 2, 2018, 06:26 AM
    Hi Doug

    If you have integral shutoffs... open them all the way.

    Next, be sure both hot and cold water are on to the shower...if both hot and cold water pressure is not received by the valve it will not work (pressure balancing spool locks the cartridge shut).

    If that isn't the issue, shut the water off, remove the cartridge inside the valve body and flush the valve body by turning water back on for a few seconds (pull shower curtain over the area to keep water from coming out onto floor). Reinstall the cartridge and check out the flow to the tub ad shower now.

    If you get water out of the valve without the cartridge in place and no water out of the valve when you reinstall the cartridge then most likely, the cartridge has become clogged and will need to be replaced (A.S. cartridges cannot usually be cleaned once they get clogged hard).

    Also, check the shower head by removing it entirely and clearing the screens (in head and neck of shower head)... these easily clog!

    Start there...

    Mark
    dougupnorth's Avatar
    dougupnorth Posts: 2, Reputation: 1
    New Member
     
    #3

    Jun 4, 2018, 06:12 AM
    Thank you for quick and smart response. I appreciate it. One more question what is the integral shut off?

    Thank you for quick and smart response. I appreciate it. One more question what is the integral shut off?
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Jun 4, 2018, 12:34 PM
    Hi Doug

    The integral shutoffs are shut offs on the hot and cold side of the shower valve (look like slotted screw heads left and right side of the valve). Most shower valves do not have them, but if you have slotted screws (need to remove the shower trim to see them) under the finish trim then that could be an issue is all.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Water made some loud noise than stopped coming out, kenmore model 106.4442*600 also 2 [ 1 Answers ]

Kenmore model # 106.4442*600 the water dispenser made some loud rattling noise, and stopped coming out. Now getting 2 flash code repeating.

Covina pressure balancing bath/shower set 9090.501 & 9090.502 no cold [ 4 Answers ]

Pressure balancing bath and shower set.very little cold water outlet.Hot water OK

Aqua Air Model V60 pressure tank, water is coming out of safety valve [ 14 Answers ]

I have a Aqua Air Model V60 pressure tank. When water is used, the pump runs and after it stops, water comes out of the safety valve (about half a cup). The pressure gauge above the safety valve shows 62 psi. Tank is showing 44 psi. Do I need to replace the safety valve?

No hot water coming out of hot side of faucets but water coming out of cold [ 1 Answers ]

Had breaker to elecric heater turned off for couple months after turning back on the cold water works but there is no water at all coming out of hot side. There;s only one valve and its turned on what is the problem?


View more questions Search