    Replacing a 3 speed ceiling fan zing ear
    I have a hunter ceiling fan. The fan chain switch went. It was a zing ear #ZE-268S6. I replaced it with a Westinghouse zing ear #77288. Replaced wires as follows
    L-black. 1-gray. 2-brown. 3-green.
    Now the fan only has high & medium. And does not shut off with the pull chain I need to shut the switch.
    Any thoughts on how to make it work. We tried switching the wires around. Still didn't work
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Apr 11, 2014, 06:58 PM
    Why did you use a different part, they are not all the same. PULL CHAIN SWITCH
    speedracer1000's Avatar
    speedracer1000 Posts: 1, Reputation: 1
    New Member
     
    #3

    Mar 14, 2015, 03:46 PM
    OK, I have a workaround fix...
    I too have a Hunter ceiling fan and replaced the original Zing Ear (because the fan chain switch broke off) with the Westinghouse zing ear #77288.

    Same problem you had when I did: L-black. 1-gray. 2-brown. 3-green, got high & medium and won't turn off:

    I switched 2 wires:
    L-green. 1-gray. 2-brown. 3-black

    Now it does turn off but the speed sequence changed.
    It starts at medium > low > high > off

    I can live with this (hopefully it doesn't blow up because other sites say "black always go to the L connection")

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replacing a switch on a ceiling fan to add another speed [ 0 Answers ]

Is it difficult to replace a switch on a ceiling fan so I will get medium speed again?

Replacing an old 3 wire speed switch for ceiling fan [ 0 Answers ]

Hi, I have an old ceiling fan. The chain of the speed switch broke and the fan stayed on constantly. I bought a 3-4 wire switch. The old switch had only 3 wires ! (no place for a fourth) The wires were organized red, blue, black. There are no numbers or letters on the old switch. Next...

Ceiling fan replacement switch, zing ear a05 possible candidate [ 3 Answers ]

As most on here, one of my ceiling fan's speed control switch exploded, linking to the inevitable run to Lowe's only to find out that the standard switch is a no go. Which in turn lead me here, I have tested the wires to see what combinations got me where and here are my results (mind you, w/ the...

Replacing a 3 speed ceiling fan switch [ 1 Answers ]

I'm trying to replace a 3 speed ceiling fan switch. I thought I removed and replaced all wires correctly but obviously not. The colors are green,gray,black, and brown. Positions on the switch are 1,2,3 and L.

Replacing the zing ear switch in a ceiling fan [ 2 Answers ]

I have found the correct zing ear switch to replace the existing one , in which the chain broke off. I was able to remove the 4 wires from the old switch by placing a small flat head screwdriver in each slot and pulling each wire. How do I insert the 4 wires into the new switch? Do I need to...