    What is an angle stop in a plumbing fixture
    I had a new electric water heater put in and now I an getting hammering noise when I turn on hot water. I turn on cold water first and I don't get the noise what can I do to fix problem
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    Feb 3, 2014, 02:48 PM
    Angle stops are the valves under sinks and toilets. Where is the hammering? Only when you turn the water on? Could be an unsupported hot water pipe somewhere in the line
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Feb 3, 2014, 04:18 PM
    Great explanation by Brian. Here is what one looks like (see image).

    Let me address your water hammer problem.
    "Water hammer" happens when you abruptly shut off the water. You have at least 40 pounds of pressure pushing the water flow. The weight of the water hitting a 90 degree bend causes the sound that you hear. We put in air chambers to cushion the hammer much like the shocks on your car.
    Back in the 60's we were required to to put air chambers on all bath lavatories and kitchen sinks. Over time water and condensate built up in them and they must be recharged. First turn off the house at the main house shut off valve. Then open hot and cold faucets at the farthest bathroom to prevent air lock.(this is important.) You will find under each fixture little brass or chrome valves. These are called angle stops. With a small pail held under the angle stop to catch the run off look under the handle of the stop and you will see a nut with the stem running through it. This is called the bonnet packing nut. Put your wrench on it and back it off counterclockwise. Now open the stop and remove the stem and washer assembly, The stop will began to drain. When it has quit draining reassemble the stop and move on to the next one. Do this on each one of your angle stops. There will be six of them in a two bath home. When you are done, close off the faucets you have opened, turn on the water to the house, and give yourself a pat on the back.
    You have just recharged your air chambers and saved yourself a hefty service call bill. Hope this helps you out and thank you for rating my reply. TOM
    Attached Images
     
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #4

    Feb 3, 2014, 08:42 PM
    It can be number of things: angle stops, pressure balanced shower fawcet, reversed hot water nipple with back-flow device inside located on top of water heater, loose part in any plumbing device / valve / regulator. unsecured pipes etc...

    Try to CLOSE and OPEN all angle stops first. See if the noise continues...

    Back to you / Milo

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Angle stop one piece [ 4 Answers ]

How do you remove them??

Angle stop for dishwasher [ 5 Answers ]

How do you know if the stop is open or shut? Vertical or horizontal?

Angle Stop [ 1 Answers ]

Have you heard of an angle stop with a plastic knob that you should pull for water shut off to the fixture? My Mother has these in her house and can't seem to pull them out for water shut off.

Angle stop leaking [ 3 Answers ]

I recently installed new "fill valve & flapper" to my toilet. Basically all of the insides of the toilet. It was leaking at the bottom of the toilet so I added a washer wich fixed that leak, but now it leaks at the angle stop. I bought some teflon tape to use to try to use at the connection of...

Angle stop [ 3 Answers ]

What is a standard 1/2" compression angle stop? I am installing a sink faucet supply line


View more questions Search