New Member
|
|
Apr 7, 2007, 05:35 PM
|
|
Building a washroom in the basement
I am planing on building a washroom in my basment. The problem I have is that I don't have any extising swer or dranage lines where I am planing to build.. I am thinking of using the flood drain line to hook up my dranage and swer lines. Is this a good idea? Do I have to take in to consideration a vent line as well?
|
|
 |
Eternal Plumber
|
|
Apr 8, 2007, 07:02 AM
|
|
What fixtures will your washroom have? This "flood drain line", where does it connect to and what's connected to it at the present time? And yes, you will have to vent your bathroom group. Let me give you a typical basement bathroom rough in. Most bathroom groups are roughed in like this.
Toilet connects to sewer main or the stack vent. Lavatory connects to toilet drain and runs a vent off the top the stubout tee out the roof or revents back into a dry vent in the attic.. The toilet wet vents through the lavatory vent and the tub/shower connects to the lavatory drain and is wet vented by it. This is a normal rough in and is acceptable both by local and state codes and also The Standard Plumbing Code Book.
Let me know about the "flood drain line". Regards, Tom
|
|
 |
New Member
|
|
Apr 9, 2007, 04:43 AM
|
|
 Originally Posted by speedball1
What fixtures will your washroom have? This "flood drain line", where does it connect to and what's connected to it at the present time? And yes, you will have to vent your bathroom group. Let me give you a typical basement bathroom rough in. Most bathroom groups are roughed in like this.
Toilet connects to sewer main or the stack vent. Lavatory connects to toilet drain and runs a vent off the top the stubout tee out the roof or revents back into a dry vent in the attic..The toilet wet vents through the lavatory vent and the tub/shower connects to the lavatory drain and is wet vented by it. This is a normal rough in and is acceptable both by local and state codes and also The Standard Plumbing Code Book.
Let me know about the "flood drain line". Regards, Tom
Hi Tom,
Thxs for the reply. The fixtures are a shower, toilet,washbasin. The flood drain line connect to the main line. At this time there is only the drain attached to it. Won't the flood drain already be vented?
Regards,
Rohan
|
|
 |
Eternal Plumber
|
|
Apr 9, 2007, 06:30 AM
|
|
" At this time there is only the drain attached to it. wont the flood drain already be vented?"
Not if the only fitting attached to it is a floor drain. A floor drain is the only trapped fitting that doesn't require a vent. No my friend, your basement group will have to go down exactly as I presented it. Since the floor drain's going to be your lowest point in the system you might considder installing a floor drain Flood Guard,(see image) on it to prevent any unwanted back ups.
Good luck, Tom
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Building a shower base in the basement
[ 7 Answers ]
A while back, I talked with Doug, about building a shower base. He told me that using thin set mortar was not correct. Luckily, I re-read the book I am using and found out he was right... you have to use concrete... sorry Doug, but I did listen enough not to go head long into the project without...
Building a shower base on an unsealed cement basement floor
[ 6 Answers ]
I am going to build a show base, 3' by 5' on a basement floor. The drain has already been placed in the middle of the 3by5 area.
On two of the sides there will be 4" cement footers poured to be the foundation of the outer walls of the shower stahl. These walls will be glass block.
The other...
Venting for basement washroom
[ 1 Answers ]
We are looking to install a washroom (toilet and sink) in our basement. There is a rough-in for the toilet - black pipe with cap- but no other pipes visible. Our home is about 5 years old, and this was installed at the time of construction.
We have been told that in order to vent the toilet and...
Building a 1/2 Bath in an Unfinished Basement
[ 5 Answers ]
Hello all. This is my first post on this forum. :)
I want to build a 1/2 bath and separate utility room in my unfinished basement. The utility room will be behind the bathroom (in front of, going by the orientation of the first picture below) and hide the heat pump fan coil (air handler),...
View more questions
Search
|