Ask Experts Questions for FREE Help !
Ask
    swflhoneowner's Avatar
    swflhoneowner Posts: 5, Reputation: 1
    New Member
     
    #1

    Oct 28, 2013, 11:20 AM
    My well system has air in the lines AND low pressure AND pump will not cut off
    Please Help! We have a submersible system.. Only 5 yrs old.. (Originally pressure on system was high.. We lowered it which stopped the above ground pipes from bursting again there is no pressure valve to know exsctly the setting.) we have had air a while.. Not a huge conscern as we suspect our faulty arerator.. As it continually regenerates... Planned on repkacing as soon as we get money.. MAIN WORRY PUMP WILL NOT TURN OFF! Two days ago we noticed about half pressure in our home suddenly (thought it was ehole house filter but as before but we had forgot to replace last time do it was not clogged) hubby noticed pump was continually running.. At switch it can manually be turned off.. (Aka not melted together) we r having to unplug pump until we figure this out so it doesn't burn up (and idnt using all of thst electric which is HIGH here in lehigh acres, fl) ANYONE PLEASE ADVISE US! First troubleshoot so far:Hubby replaced check valve (when we only knew of air issue) by tank (as he is busy) working during daylight. He plans on pulling pump up soon but we have no idea! Any advise? Is well going dry and pump bad? Why is it not cutting off (only will with no electric)
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    Oct 28, 2013, 05:27 PM
    There should be a pressure gauge. When the pump is running, what does the gauge read?
    swflhoneowner's Avatar
    swflhoneowner Posts: 5, Reputation: 1
    New Member
     
    #3

    Oct 29, 2013, 04:21 AM
    There is absolutley no gauge.. Ugh.. But it feels like holding steady at about no more than half the output than normal.. We had a HARD time lowering pressure before... Read a site to know.. don't know how to instal a gauge or if one can be temp set up... Hubby wants to attempt today!
    swflhoneowner's Avatar
    swflhoneowner Posts: 5, Reputation: 1
    New Member
     
    #4

    Oct 29, 2013, 04:24 AM
    I definitely can say a gauge would say its low.. It just will not turn off loss of pressure seemed sudden... We had air earlier this year we accounted to our defunct areator that keeps regenerarung and lack of check valve. Check valve by well tank is there now.
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #5

    Oct 29, 2013, 01:58 PM
    Do you have a bladder style pressure tank? It would be painted. If it is a galvanized tank, then different story, but assuming it’s a bladder tank, there is a little air valve at the top. You can use a tire pressure gauge and get a fairly accurate reading from there. It would be nice to know that reading. If it's low, then you think pump problem. If it's fairly high, say 30 to 50, then you might have a switch problem or something going on with the filter.
    swflhoneowner's Avatar
    swflhoneowner Posts: 5, Reputation: 1
    New Member
     
    #6

    Oct 29, 2013, 04:12 PM
    Quote Originally Posted by jlisenbe View Post
    Do you have a bladder style pressure tank? It would be painted. If it is a galvanized tank, then different story, but assuming it’s a bladder tank, there is a little air valve at the top. You can use a tire pressure gauge and get a fairly accurate reading from there. It would be nice to know that reading. If it's low, then you think pump problem. If it's fairly high, say 30 to 50, then you might have a switch problem or something going on with the filter.
    Well hubby found out answer.. The pipe right above the joint connecting pump to pipe had a very tiny crack in it! Removed/cut that part put a coupling in to reconnect pipe together let dry it worked perfectly! Like brand new! My father in law insited he now add that pressure gauge on.. Pressure was dead on.. (But remember earlier this year it had been set too high to the point pipes next to well burst) pressure is now high and so far seems clear of air.. (Despite the arrerator continually regenerates [running water] 24/7.. ) THANK YOU FOR YOUR HELP!
    swflhoneowner's Avatar
    swflhoneowner Posts: 5, Reputation: 1
    New Member
     
    #7

    Oct 29, 2013, 04:18 PM
    Quote Originally Posted by swflhoneowner View Post
    Well hubby found out answer.. The pipe right above the joint connecting pump to pipe had a very tiny crack in it! Removed/cut that part put a coupling in to reconnect pipe together let dry it worked perfectly! Like brand new! My father in law insited he now add that pressure gauge on.. Pressure was dead on.. (But remember earlier this year it had been set too high to the point pipes next to well burst) pressure is now high and so far seems clear of air.. (Despite the arrerator continually regenerates [running water] 24/7.. ) THANK YOU FOR YOUR HELP!
    Oh indeed it was a bladder tank... I hope this helps the next person with this problem!
    Still have that enclosed outdoor arrator regenerating 24/7.. Ugh I guess I need to submit a new thread! One problem fixed! I love this site!
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #8

    Oct 30, 2013, 05:20 PM
    Congrats! Good detective work.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

When well pump turns on I get air in my lines why [ 2 Answers ]

I just replaced my water tank to a blader tank , and replaced my check valve to . When the pump turns on I get air pushed into my water lines what would cause this ?

Low water pressure and sound slike air in lines [ 1 Answers ]

We have a well Meyer pump and H2Ow-to pressurized water tank.. We hardly have water pressure and when we do it's not for too long. Sometimes when you flush the toilet or turn on a faucet it sounds like water in the lines and then when it does kick sometimes it will blow out some sediment. The pump...

New pool pump motor... low pressure low return flow [ 3 Answers ]

We bought a home with warranty,the pool motor and timer went out... repair company replaced the motor and internal timer mechanism... it is 1 horse 220 volt system... had an eplus motor on it and the pressure was about 10 to 12 pounds on the gauge and the return flow was obvious...

Low pressure cut-off switch problem [ 4 Answers ]

My well occasionally runs dry, so I recently replaced my pressure switch with a Square D switch with the low pressure cut-off to protect the pump. It is set for a 40-60 psi range (same as the old one). Now about half the time, when when it reaches the 40 psi cut-in, the pressure suddenly drops...

Tank Pressure vs Pump Cut Out Pressure for Well [ 1 Answers ]

I am trying to increase my water system pressure to the minimum required 40 PSI to feed my reverse osmosis drinking water filter. However, the 33 gallon pressure tank for my well pump system says it is pre-charged at 30 PSI and that the cut in pressure for my pump should be set equal to that 30...


View more questions Search