    replacing seco 24 vac ta2000 stat with a honeywell ct3611- does the black w go
    I am replacing a Seco 24 VAC TA2000 with a Honeywell CT3611thermostat. On the SECO, Black wire is currently connected to E and blue is connected to X .

    From the Honeywell's previous wiring connection to a similar system, the blue wire was connected to Honeywell's C. All other wires are connected to the corresponding color's letter - although white is connected to Honeywell's W2. There is a jumper from Honeywell Y to W1.

    There is a Black wire on the Seco stat connected to it's E terminal on the far right.

    Where does this black belong on the Honeywell?

Check out some similar questions!

SECO TA2000 Heat Pump Thermostat manual [ 0 Answers ]

I need a wiring diagram for the SECO TA2000 Heat Pump Thermostat

Replacement of SECO TA2000 Heat Pump Thermostat [ 3 Answers ]

I would like to replace the current SECO 24 VAC TA2000 Heat Pump Thermostat. I want to put in a programmable thermostat as a replacement. Would like to know brand names that are a "good" replacement for the old model. Current thermostat has one line coming from the wall, then 6 wires coming from...

Replacing an old ta2000 with a rth3100c... How? [ 0 Answers ]

the old ta 2000 is wired like this w2-black O-pink X-blue R-red Y-yellow G-green E-brown according to http://www.mobilehomerepair.com/media/img/coleman/119005.pdf y is 1st stage w2 is second stage g is fan r is switched side class2 power single source x is inswitched (common)...

Room gets too cold-calibrating a SECO TA2000 thermostat [ 1 Answers ]

Now that it is the summertime the air conditioning in my apartment runs so that the apt. gets TOO cold according to the setting on the thermostat. In order to get it shut off, I have to set the indicator on the thermostat so that it is 80 in order for the unit to shut off. Is there any way to...

Replacing honeywell stat to an other honeywell stat [ 19 Answers ]

I'm switching my old stat to a new one that lets me enter a program. I have an electric central air furnace and a thermopump outside that provides heat and AC. I'm going from a honeywell CT3600 or so (looks the same as in the manual for that one but without the program buttons) to a RTH8500....


View more questions Search
 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.