Ask Experts Questions for FREE Help !
Ask
    KALLEY-2's Avatar
    KALLEY-2 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jun 12, 2013, 12:29 PM
    Well pump won't shut off and only low pressure
    A couple of months ago I had to replace my well pressure tank,pressure switch and gauge. Now my well pump won't shut off,only 30-35# pressure.. doesnt seem to be getting water in tank either(tank light).. what is wrong? when I turn the breaker off my gauge goes to zero... pease hep fast!
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    Jun 14, 2013, 04:41 AM
    when I turn the breaker off my gauge goes to zero
    Sounds like a bad footvalve, assuming this pump is above ground. Can you tell us some more about your setup? How deep is the well? Why did you change the switch and tank earlier?
    1speedbump's Avatar
    1speedbump Posts: 8, Reputation: 0
    New Member
     
    #3

    Jun 14, 2013, 06:51 AM
    You probably haven't overcome the precharge in the tank. Water won't go into the tank until the pump goes higher than the tanks air pressure. We need to know what kind of pump you have to make any guesses about why it won't make pressure.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Jun 14, 2013, 07:14 AM
    Jlisembe nailed when he said you had a faulty foot/check valve. The gage falling back to zero tells you that. Good catch by "J". Tomn
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #5

    Jun 14, 2013, 03:44 PM
    Now my well pump won't shut off,only 30-35# pressure
    That's a separate issue. As Speedball said, the footvalve would sure seem to be bad, so take care of that first. As to the pressure issue, if we continue to assume this pump is above ground, then the pump becomes suspect. The pressure tank is not the problem and don't worry about it being "light". That is common when you install a new pressure tank.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

What do I do if the pressure handle on delta 2300 series shower valve water won't shut [ 1 Answers ]

What do I do if the pressure side on my Delta 2300 series doesn't turn the water off anymore

Fuel pump shut off by low oil pressure? [ 0 Answers ]

1989 GMC K1500 5.7 liter TBI engine 4L60C trans Can anyone confirm if there is a sensor to shut power to the fuel pump if oil pressure is lost. A friend om mine is positive it exists but can't tell me where it is and how it works. Any info would be appreciated.

New pool pump motor... low pressure low return flow [ 3 Answers ]

We bought a home with warranty,the pool motor and timer went out... repair company replaced the motor and internal timer mechanism... it is 1 horse 220 volt system... had an eplus motor on it and the pressure was about 10 to 12 pounds on the gauge and the return flow was obvious...

Low pressure on old well. Pump doesn't shut off. [ 6 Answers ]

Hi, We have city water, but when bought our house, they left an old well set up in the basement. Other then the outgoing pipes capped off, everything still works. There is a pipe coming from outside into the basement. It leads to and older 1/3 HP pump with an ON/OFF switch. It's connected to...

Water shut off now low pressure in 1 tap only [ 2 Answers ]

Had to shut the water off to whole home for a fixit. Did the repair and turned water back on. Bled all lines and all taps/fixtures are fine except sink in master bath which just trickles. Was running fine before shut off. Any ideas? Thanks in advance.


View more questions Search