    Tluttre's Avatar
    Tluttre Posts: 4, Reputation: 1
    New Member
     
    #1

    Oct 4, 2012, 05:19 PM
    Extremely tight (6 inches) clearance between bottom of sink and cabinet floor
    Bought a display vanity from a cabinet mfg. that had never been plumbed. The design has a deep sink installed within a 18" tall by 24" deep cabinet. There is only 6" between the bottom (hole) of the sink and the cabinet floor. I can't find a ptrap / tailpiece fitting what will fit within the 6" clearance shown in the attached pictures.

    The area below the 18x24 cabinet is open and a ptrap hanging in that area would detract from "the look".

    Any ideas?
    Tluttre's Avatar
    Tluttre Posts: 4, Reputation: 1
    New Member
     
    #2

    Oct 4, 2012, 05:24 PM
    Sorry, did not attach the picture.
    Attached Images
     
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #3

    Oct 4, 2012, 05:41 PM
    Hi Tluttre

    Where is the waste pipe from the wall? At what height/relation is that to your cabinet... that will tell us how we can help you here... ;)

    Mark
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #4

    Oct 4, 2012, 05:46 PM
    With the sink that low, you will have trouble getting any drain. You may find that the wall piping is above the sink base and water will not flow from the sink. You could possibly use an S trap with a "T" and an AAV, similar to what they use in log homes where water drains through the floor. S traps are not code accepted but can be modified with an AAV.
    Tluttre's Avatar
    Tluttre Posts: 4, Reputation: 1
    New Member
     
    #5

    Oct 4, 2012, 06:09 PM
    Mark,

    The wall waste pipe will need to be moved because the sink is about 2 feet to the left of the original sink location. So, I can plumb it at any height / relation to the new sink that works.

    Thanks for your quick response.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #6

    Oct 5, 2012, 02:22 PM
    Actually, looking at this, if you get a pop-up assembly (you called it a tailpiece fitting) and you cut the tailpiece so it is about an inch long, a regular ptrap with an 1.5" PVC x 1.25" compression trap adapter (also called a desanco fitting) should work here. They also sell a STREET desanco fitting (cements directly into the trap)... adds another 1" to help, if needed.

    I would dry fit everything... cut the tailpiece... and then take the measure of the setup so you can decide EXACTLY where to bring your drain pipe into the cabinet.

    I'm pretty sure all this will work with standard fittings.

    Let me know what you think, OK?

    Mark
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #7

    Oct 5, 2012, 09:18 PM
    It appears to be a floating ( wall mounted ) cabinet. Correct ? If so, you can also drill 1 1/2" hole and run pipe through it. Use nice, chrome, metal P-Trap. Milo
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #8

    Oct 6, 2012, 05:26 PM
    Hey Milo..

    Do they still allow a compression fitting AFTER the trap in California? Just curious is all! In Mass, you can't use the old-fashioned chrome traps with a compression fitting (trap adapter) after the trap (been that way for a long time). Do they still allow in Cali. Let me know, OK?

    Mark
    Tluttre's Avatar
    Tluttre Posts: 4, Reputation: 1
    New Member
     
    #9

    Oct 7, 2012, 02:04 PM
    Mark,

    Looks like that will be a good option. Thanks for the advice.

    Tom
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #10

    Oct 9, 2012, 06:18 PM
    :)

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Under sink kitchen cabinet floor [ 3 Answers ]

What is a good way to refurbish the cabinet floor under the kitchen sink?

25 inches Hairline cracks in fiberglass bathtub bottom [ 7 Answers ]

I just bought a brand new home and moved in about 2 weeks ago. Then I found there is a 25 inches of hairline crack in the bottom edge of garden bathtub. The builder said it can be repaired and I won't even noticed it, and it will not leak forever. I believe it need to be replaced just because...

Cabinet bottom dropping out [ 5 Answers ]

I have JUST finished painted all the cabinets in the kitchen and are replacing the range hood which is under a set of cabinets. Unfortunately, the cabinets are made of Formica and once the old hood was removed we found that the bottom of the cabinet was wet and falling out. Evidently rain has...

Hinged shower door (framed) bottom clearance [ 1 Answers ]

What is the recommended clearance (bottom) for a hinged framed shower door

Water damage to cabinet bottom under sink [ 2 Answers ]

I had a leak under my kitchen sink which has caused some water damage to the bottom of the cabinet. Structurally it is fine, but I wanted to make the bottom look better. What is the best way to repair this (I have already repaired the leak)? I have purchased a thin sheet of wood to place on top...


View more questions Search