    Jet pump runs too long
    I have replaced the 30 gallon bladder pressure tank with a 50 gallon because of the amount of water draws in and outside the home, I have also replaced the square D pressure switch from a 20/40 to the new 30/50. The pressure in the tank when empty is set with the MFG suggestion at 2# less than the pressure switch and is correct when filled. The Shallow jet single line pump runs 7 to 10 minutes to refill the tank. It appears that the needle on the gauge for the pressure switch barely moves when it gets to 40 pounds of pressure. And if someone in the household is using the water while the pump is cycling it runs for 15 minutes or longer until the water has been turned off. I have a 3 inch well not sure how deep the water table is. The pump appears to be old just by looking at it.
    I don't get any air in the water lines and the water line never looses prime. Is this telling me that the pump is in need of being replaced or rebuilt? Thanks Dave
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Apr 20, 2012, 06:04 AM
    the tank when empty is set with the MFG suggestion at 2# less than the pressure switch
    That doesn't tell me what you charged the tank at. The cut in or the cut out point. I realize it's obviouse to you but it's not to me.
    because of the amount of water draws in and outside the home,
    Tell me more about the water usage.. How many in your family? How many females? (They use more water then us guys do). What's the pump supplying outside the house? Could it be that the impeller on the pump is faulty? How old is the pump? Back to you, Tom
    Dave Snowberger's Avatar
    Dave Snowberger Posts: 3, Reputation: 1
    New Member
     
    #3

    Apr 20, 2012, 06:52 AM
    Quote Originally Posted by speedball1 View Post
    That doesn't tell me what you charged the tank at. The cut in or the cut out point. I realize it's obviouse to you but it's not to me.
    Tell me more about the water usage.. How many in your family? How many females? (They use more water then us guys do). What's the pump supplying outside the house? Could it be that the impeller on the pump is faulty? How old is the pump? Back to you, Tom
    28 psi empty for a 30/50 switch. 2 male and 2 female
    Water supply out side the home. Water spics for garden hoses.
    The house is new to us however over 50 years and the pump looks like it too.
    Dave.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Apr 20, 2012, 07:08 AM
    Hi Dave,
    I was sure the bladder tank setting was correct I just wanted to have you verify it. It sounds like your pump may be at fault. I'd have a pump guy check it out and replace if necessary. Good luck, Tom
    Dave Snowberger's Avatar
    Dave Snowberger Posts: 3, Reputation: 1
    New Member
     
    #5

    Apr 20, 2012, 09:26 AM
    Quote Originally Posted by speedball1 View Post
    Hi Dave,
    I was sure the bladder tank setting was correct I just wanted to have you verify it. It sounds like your pump may be at fault. I'd have a pump guy check it out and replace if necessary. Good luck, Tom
    The cost of the pump is minimal compared to the years of use that we will get out of it. We bought a newly renovated foreclosure, everything is new! Except the pump of course. I hate to think about the persons misfortune that had lost this place. If only their bank would have worked with this person, they would still have all that they have invested. 196,000 for 42,000.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pump lost prime and overheated motor runs but does not pump is the pump fried [ 4 Answers ]

Over night the pump lost primed and melted the sched. 40 fittings I replaced all the fittings and cannot get pump to prime the motor runs is it possible that the propeller was damaged from the heat?//

Pump runs to long [ 1 Answers ]

I have good pressure, bladder tank seem to be full of water. The pump runs to long after it reaches 50psi

Jet well pump [ 2 Answers ]

Can't get 1 hp jet pump to prime. Ran well dry two days ago well filled back up but can't get to prime. Any and all help would be great

What are the benefits of a piston pump compared to a jet pump? Which is better? [ 0 Answers ]

Which is better , piston pump or a jet pump? What benefits do a piston pump have compared to a jet pump?

Pump Runs and Runs Even When No Heat Is Needed [ 1 Answers ]

I have a 4 zone hydronic heating system. It is a 15 year old Hydrotherm HI-B series boiler with a new circulator pump. It has been noticed that when none of the zones call for heat and the boiler is back up to temperature the pump continues to run, a waste of power since al the zone valves are...


View more questions Search