    Installing the Inline Water Filter
    There is the ice maker line from the water heater main piping, it has a saddle
    Water cut off valve. Do you think I can use compression fitting
    Rather than soldering. I am not too good at soldering. I wonder what type of water filter should I buy. See Picture. I do not see the upload for pictures
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Apr 17, 2012, 01:37 PM
    Hi Pastor1189

    Are you thinking about removing the saddle valve and installing a new 5/8" compression x 1/4" compression stop (see image) to supply the new ice maker line? If so, that would work fine.. compression is very trustworthy... just follow directions and do NOT overtighten and do NOT use pipe dope on the compression ferrules/nuts, OK?

    In terms if which ice maker filter, I'm pretty sure they are all just basic carbon filter systems (see image), so whichever one you purchase just make it readily accessible because, as mentioned in your previous thread on this subject, you will need to change out these ice maker filters every so often (depending on use).

    Back to you...

    Mark
    Attached Images
      
    pastor1189's Avatar
    pastor1189 Posts: 1,538, Reputation: 3
    Ultra Member
     
    #3

    Apr 17, 2012, 02:01 PM
    If I did replace the saddle valve. How would I cut off the water supply.
    I guess at the water heater
    pastor1189's Avatar
    pastor1189 Posts: 1,538, Reputation: 3
    Ultra Member
     
    #4

    Apr 17, 2012, 02:05 PM
    [QUOTE=pastor1189;3087671]If I did replace the saddle valve. How would I cut off the water supply. I guess at the water heater . If I installed the filter after the saddle
    Valve, I could cut off the water.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #5

    Apr 17, 2012, 04:21 PM
    You could use a tubing cutter or a mini-tubing cutter to cut the copper pipe and then install the compression shutoff.

    After the compression shutoff is installed you'll install the ice maker filter which will come with its own 1/4" compression fittings and then connect to the 'fridge to finish the job.
    Attached Images
       
    pastor1189's Avatar
    pastor1189 Posts: 1,538, Reputation: 3
    Ultra Member
     
    #6

    Apr 17, 2012, 05:20 PM
    Quote Originally Posted by massplumber2008 View Post
    You could use a tubing cutter or a mini-tubing cutter to cut the copper pipe and then install the compression shutoff.

    After the compresion shutoff is installed you'll install the ice maker filter which will come with its own 1/4" compression fittings and then connect to the 'fridge to finish the job.
    Thanks a million. I got it.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search


Check out some similar questions!

Have GE refrig; water leaks from smart water filter inside; get water;makes no ice? [ 0 Answers ]

Water does come out of the water dispenser with no problem. The Smart Water filter overflows INSIDE the refrigerator. No ice is being made. Heavy frost accumulates inside freezer from ice maker.

Water Filter that will Filter Calcium [ 4 Answers ]

My husband is having trouble with kidney stones and they seem to be calcium stones. We would like to get a under the sink filter system that will filter the calcium (among other things). Can you suggest a good filtration system. We have well water. Thank you! :)

I'm installing an under the sink water filter.Yikes. [ 9 Answers ]

Hi, I am trying to install an under the sink water filter. I understand I am supposed to unscrew the line from the shut off valve to the tap and connect a T adapter... my question is... that under the sink... I have two shut off valves for both the hot and cold water, One on the top and one on...

Pvc inline water supply shut-off valve replacement [ 1 Answers ]

I have a 1 1/2" (one and one half inch) pvc water supply line that leaks at an inline shut-off valve (1/4 turn type, I assume). I realize I need to shut off the supply upstream to change it out. The valve is in between 2 elbows, about 3' (three feet) apart, so there is 'room to work' to remove the...

Installing direct inline sewage vent [ 1 Answers ]

I have a mobile home with the typical roof vents for sewage. After setup, the system is not draing properly. Everyone says I need another vent for sewage in addition to the one through the roof. Can I install one directly in the main sewage line, specifically near the clean out? If so, what exactly...


View more questions Search