    How do I wire up my new condenser motor .
    The new motor has 4 wires . Yellow, brn/wht ,brn ,black .
    The old motor has 3 wires / blk,brn,orange .
    thermalmedics's Avatar
    thermalmedics Posts: 153, Reputation: 13
    Junior Member
     
    #2

    Apr 3, 2012, 08:35 PM
    Usually brn-wht and brown to the new run cap and yellow and black to contactor and defrost board/relay if heat pump or both to line side of contactor if straight cool a/c

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

How do I wire up my new AC condenser fan motor? [ 7 Answers ]

My new AC condenser fan motor has an extra wire. What do I do with it? AC is a 1996 SEER 12 Rheem. New motor is an A.O. Smith 1/8 HP 208 RPM 208-230 volt. Old motor has 3 wires, black, brown, and orange. New motor has 4. Black, brown, orange, and brown with a white stripe. Does anybody...

Replacing a Rheem 5 wire condenser fan motor with an Emerson 4 wire condenser Fan [ 0 Answers ]

I have a Rheem a/c unit that the fan motor quit. I took all the information off the old motor and went to a local supply store and they cross-referenced the numbers and gave me and Emerson motor. All the specs are the same, 1/5 HP, 1075 RPM, 60 Hz, 1.3 Amp, single phase. When I got home, I took...

Emerson motor condenser wiring replacing 3 wire motor with 5 wire. [ 5 Answers ]

Any recommendations? New motor apparently is capable of running in either direction by switching brown and purple wires going to the capacitor. Looks like then either the remaining brown or purple is spliced to or hooked up to the same terminal as the yellow. Thanks.

How do I wire up a new condenser fan motor [ 5 Answers ]

The old condenser fan motor (EMERSON model # is K48HXFCN-3727,HP-1/8,v 208-230,rpm 1075with 3mfd 370vac dual capacitor) is making a noise.When I got a new one (EMERSON model#is K48HXTMG-4003 HP-1/8,v208-230,rpm1075 come with 5.0mfd 370vac capacitor). I am confused, I need help trying to do the...

Change 4 wire condenser motor to 3 wire motor [ 4 Answers ]

I need TO know how to wire a condenser motor. The one I am taking out is a 230 volt it has 2 brown capacitor wires and a black and white. The one I want to put in is a 230 volt/5 mfd capacitor motor. This one has a red wire a black wire and only one brown capacitor wire. How do I retrofit this....


View more questions Search