    Must a residential toilet be vented through the interior of the structure to the roof
    Plumbers have run a first floor toilet vent in a log home through the ceiling of the first floor and into and through a room in the second floor to the roof. Because it is a log home, the vent is visible -- and unsightly. Is there any reason why the vent cannot be run through an exterior first floor wall and then outside of the structure and up to a level above the roof line?
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    Mar 25, 2012, 09:07 PM
    No. I have a log home and all my vents run through interior walls. Why not yours?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Mar 26, 2012, 08:39 AM
    Unless you live in a area where wet vents, (see image) are prohibited you don't need a extra toilet vent. Check with your local Building Department to be sure. Good luck, Tom
    Attached Images
     
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Mar 26, 2012, 09:03 AM
    Hi guys

    I'm thinking we are misunderstanding the question a bit..

    Mba wanted to know if a vent can be run out the exterior wall on the first floor and then run the vent up the outside of the building to above the roof line... eliminating it from the inside of the 2nd floor room the pipe was run through earlier.

    Here, some codes will allow that, but he would need to talk directly to the local plumbing inspector to get approval for it. Most inspectors frown heavily on this practice.

    Some codes may even allow an AAV (mechanical vent) to be installed as long as it remained "readily accessible" for future swap out... this would keep the vent in the first floor bathroom. Again, here, Mba would need the plumbing inspector to approve or deny.

    One other option I could think of would be running the vent in question up through a 2nd floor CLOSET... stuck back in a corner or even in a forward corner of the closet... would almost never be seen that way.

    And my guess is that this "toilet vent" is actually a vent for a 1/2 bath (or entire bath), but only goes vertical as 1-2" vent. This vent CANNOT be eliminated!

    Good luck!

    Mark
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #5

    Mar 26, 2012, 09:14 AM
    In addition to the previous posts: Yes, vent can be installed surface-mounted on the exterior wall. But, it HAS to be a metal vent ( Cast Iron, Copper or Galvanized Steel ). If you want to use plastic (ABS or PVC ) than you would have to box it in. Hope that helps. Milo
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #6

    Mar 26, 2012, 09:42 AM
    As codes differ from state to state and even town to town I would still strongly suggest taking this question up with the local plumbing inspector to resolve this 100%!
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #7

    Mar 26, 2012, 04:03 PM
    I have to agree with Mark on this. I would not be allowed to run a vent (of any material) on the outside of the home in my area, except up through the roof.

    Logs homes can be a real bear to plumb, all depending on the design. I think you would be best to just run the vent as Mark suggested, in a closet etc, or simply box around the existing vent. Sometimes you really just have to sacrifice a little bit with this type of construction. With some of the log homes I have plumbed, there are no closets or interior walls on the upper level, just an open area. In these cases, you just have to make your own chase for the plumbing. Please let us know what you find out from the local plumbing inspector.
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #8

    Mar 26, 2012, 04:08 PM
    Great answers guys, I too have a log home and all my vents are via interior walls up to the roof. I would think you got yourself plumber who doesn't know log homes. That vent can be zigzagged to reach a interior wall, do not put ot outside, it will look almost as bad

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Renovating older single-wide - roof structure. [ 0 Answers ]

Does anybody know if there are any structural restrictions on renovating an older Single-wide? I want to raise a roof in the cental part- above the living room. Can the walls carry more load than it was originally designed? This is in Western North Carolina, not too much snow, but still new...

Use of a Catenary Curve for a roof structure. [ 1 Answers ]

Supposedly, an inverted catery curve would create one of the most stables and self-supporting curves for a structure (See St. Louis Arch). I am an architecture student and I am currently working on a structure with a curved roof over a very large span, therefore, I would like to try to take...

Can plumbing be vented through the side of house rather than the roof? [ 4 Answers ]

We are rebuilding an old farm house and have a new steel roof. We hate the idea of putting holes in a roof that doesn't leak! Trailer vents are installed inside walls can the vents be put through the wall of the bath rooms rather than through the ceiling and roof?

Definition of residential structure or dwelling for Fannie Mae/Freddie Mac? [ 1 Answers ]

Hi! I am in desperate need of an answer! My local county defines a dwelling unit as a structure that has sleeping quarters, sanitary facilities, and cooking. Fannie Mae, as far as I can tell, defines 'dwelling unit' as a 'residential structure' but then gives no definition I can find as to what the...


View more questions Search