    Howies's Avatar
    Howies Posts: 1, Reputation: 1
    New Member
     
    #1

    Feb 27, 2012, 11:32 AM
    Floor is 2" above toilet pipe
    My toilet was seeping water from the base. I removed the toilet. My floor is 2" up from the base of the pipe. The pipe is 3". The tile floor opening is 6" in circumference. It appears I need a flange extender but the one I purchased is to tall and is a 7" diameter at the top. Even if it was shorter, it would not fit inside the existing pipe - it is 3" as well. What do I do? By the way, the tile floor is laid in with cement - old house... Thanks
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Feb 28, 2012, 01:44 PM
    Hi Howies

    What flange extender did you purchase that is too "tall"? Please let me know, OK?

    Have you looked at the 1/4"-3/8" flange extenders? Here, you can stack the extensions one on top of the other... works in most cases... see image below. You may need to enlarge the hole around the old flange using a hammer and chisel.

    You might also look into the new fernco waxless bowl ring (see other image)... this inserts into the 3" pipe and goes in pretty deep so may work nice here. The bottom of the toilet bowl MUST be free from wax to use this.

    Back to you...

    Mark
    Attached Images
       
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #3

    Feb 28, 2012, 01:47 PM
    Great answer Mark. If I ran into a toilet flange 2" recessed I'd start asking who did the floor. No plumber would install like this but I suspect someone added a new sub floor.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Toilet soil pipe is 1/2 in below fin. Tile floor how do I built concrete floor up [ 2 Answers ]

I have 2 problems,just had my bathroom floor tiled on top of concrete floor and was going to use a outside 4 in outside flange on a 4in soil pipe. I can fit over soilpipe now but tile under flange bolt down holes have no concrete under them,plus top of soil pipe is 1/2 inch below top of tile ,tile...

Second floor toilet soil pipe rattle [ 2 Answers ]

When we flush the second floor toilet the pipes rattle. This just started. It is not the fill pipes because we tested by flushing normally & then dumping a pail of water into the toilet so no tank refill occurred. In both cases the rattle occurred during the time the water drained down the soil...

Very Little "Suction" on 2nd Floor Toilet [ 4 Answers ]

Good morning, 1st time to this site. Answers seem very helpful. Here goes - I own a 2-story 1939 home. Question 1: It appears that the basement toilet and lav were added later and have their own separate vent outside -could this be correct? Basement toilet flushes fine. Question 2: 2nd...

Replacing toilet flange when pipe 2 1/4" below floor [ 4 Answers ]

I've got a 4" cast iron waste line with a slab floor. The pipe is 2 1/4" below the floor surface. The replacement flanges I have found are only 3" long. Is this 3/4" enough for a good seal? Does anyone know if there are longer replacement flanges out there? Thanks

Put in new floor, what to do with main toilet pipe? [ 3 Answers ]

We just installed a new floor in my mother's mobile home. The main pipe the toilet connects to isn't sitting on the floor. The flange on it isn't mounted to anything. The floor was installed with about a 2 inch space between it and all around the flange. The pipe itself is attached to a floor beam...


View more questions Search