    Furnace will not always light.
    I have a Frigidaire furnace 10 years old. When the thermostat clicks the fan will come on, after about 30 seconds there will be an orange glow in the burner compartment for about 2 seconds then a couple of clicks and instead of igniting it goes out and tries it all over again. I would like to fix this myself, any suggestions?
    SeattlePioneer's Avatar
    SeattlePioneer Posts: 97, Reputation: 9
    Junior Member
     
    #2

    Jan 29, 2012, 06:08 PM
    Usually the circuit board will turn on the hot surface ignitor for 20-30 seconds or so to get it white hot to light the gas. At that point the gas valve is turned on an the gas lights off the HSI.

    I take it from your description that the main gas valve doesn't turn on ---is that right?

    What color changes do you see on the HSI?


    Odds are the circuit board is defective, but it could be a bad gas valve.

    What is the make and model of the circuit board?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Propane Furnace won't start no pilot light red light flashes 3 times [ 6 Answers ]

My propane furnace G6RC has no visible flame and the red light either stays on or flashes 3 times in a row and then the furnace shuts off and tries to restart

How to light a pilot light furnace on a evcon furnace? [ 1 Answers ]

Where do I find the pilot light on a evcon furnace all I see is a on off switch?

Any danger in using propane lighter to light pilot light in gas furnace? [ 2 Answers ]

Our furnace is "forced air heat" - a gas furnace that is in the garage, and the pilot light keeps going out which we do have someone coming to fix it. In the meantime, my husband has been using a "flame thrower" to light it, (that's what I call this device He's using) as it's a small canister...

Carrier Furnace, Model: 55DRCO-45CB, how to light pilot light? [ 3 Answers ]

We have a 20 year old CArrier furnace, Series 100, Model 55DRCO-45CB. It is not heating even though the temperature gauge on the wall is on and set to heat, 70 degrees. We checked the fuse. It's fine. We don't see any pilot light--in fact, we don't even know where to look for the pilot...

My furnace won't light diagnostic light is green, & yhe thermostat says heat is on [ 1 Answers ]

Any ideas what's wrong it's a coleman mobile home furnace


View more questions Search