Ask Experts Questions for FREE Help !
Ask
    abrack's Avatar
    abrack Posts: 2, Reputation: 1
    New Member
     
    #1

    Oct 20, 2011, 03:15 PM
    Well pressure switch?
    My pressure switch keeps turning on and off even though there is no water been run or turned on in the house.
    I have checked for running water in the toilets,outside taps, etc.There seems to be on signs of running water.
    I also turned the water valve off that shuts the water from coming in to the house, and the pressure switch remained at 50 psi.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Oct 20, 2011, 03:46 PM
    Did you turn off the valve to the house and then shut the pump down to see if the pressure gage lost pressure? Back to you, Tom
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #3

    Oct 20, 2011, 07:27 PM
    That's good advice. SB suspects a leak in the well, I would imagine.

    Is your pump above ground or in the well? Either way, is there a checkvalve near the pressure tank?
    abrack's Avatar
    abrack Posts: 2, Reputation: 1
    New Member
     
    #4

    Oct 21, 2011, 03:31 PM
    Problem fixed, warped toilet flapper.
    Thank you for your input.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #5

    Oct 21, 2011, 03:37 PM
    Thanks for the update. Good luck, Tom
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #6

    Oct 22, 2011, 06:03 AM
    This one puzzled me a bit. I wondered how I managed to not suggest he look at the flapper valve. Then I noticed that he had mentioned he could cut the valve off to the house and the pressure would hold. Don't quite see how I missed that, but I did. It obviously pointed to a problem in the house, not in the well. Oh "well". Just missed that one. Glad he got it resolved in spite of my misdirections.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #7

    Oct 22, 2011, 06:44 AM
    Hi jlisenbe, My first post took it away from the pump but I was thinking a leak in the line to the house. My next question would have been to shut the house shut off to check the house supply. If the gage would have held that would have put the problem in the house but I was thinking hidden leak. I would have missed the flapper also.
    Oh well! Live and learn. Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

My gas furnace is not getting vacuum pressure for the pressure switch. [ 1 Answers ]

All the hoses were replaced as well as the pressure switch it self. I can jump it and it fires right up. It's a Heil model. The pilot light lights automatic. If you take the hose off that goes to the pressure switch and suck on it, it switches and the pilot light lights off. I don't know much...

York residential furnace pressure switch problem code stuck switch [ 1 Answers ]

I have a york furnace P2MD12H06401A after 1 hour it shuts down and gives a 2 flash error for a stuck pressure switch. The switch is new can it be wired wrong? The old one had 2 white wires piggy back and 1 blue wire. The new switch has 3 separate terminals

Pump pressure switch does not turn on with low pressure [ 0 Answers ]

I lost water in my home overnight. The pressure gage reads about 8 PSI. If I use the lever on the pressure switch to close the contacts, nothing happens. Actually, the pump controller box, makes a buzzing sound for a couple of seconds, but that's it. Does anyone have any thoughts? I don't...

Deep well, pressure tank/switch not building pressure [ 13 Answers ]

The only way I have water pressure is to leave the power on! I have replaced the 5 gallon pressure tank (28psi when void of water)/fittings/pressure gauge and tried 3 new 30/50 pressure switches and the problem remains the same. With the power off, the pressure drops to 0 (not 30). When I...

Goodman limit switch/pressure switch? [ 2 Answers ]

Hi, I've got a goodman furnace (mod. # GHT070-3) it's about 5 years old. Recently, the heat will only kick on for about 30 seconds then shut off. It's giving me 4 flashes: Open limit switch, then it kicks off. After that it gives me 3 flashes and turns back on (pressure switch). It seems the...


View more questions Search