               New Member 
              
              
              
              
       | 
        | 
      
                
               
                
                  
                      Feb 18, 2007, 09:30 PM
                  
                 
       | 
     
     
    
   | 
 
  
    | 
    
    
       
        
        
        
       
    
    
      
      
        
        Replacing Weathertron thermostat with Honeywell
       
      
    
    
    
                  
        I am attempting to replace our Weathertron thermostat with a Honeywell RTH3100C. We have a Trane heatpump system.  I am having trouble with the wiring. My wires don't match the 'less common wire designations' in the manual. 
I have the following wires on the Weathertron: 
R-red 
T-brown 
O-orange 
G-green 
Y-yellow 
X2-black 
B-blue 
W-white 
F-Pink 
and a grey wire I don't think was connected to anything-it is not taped off, and we don't remember disconnecting it, it just suddenly appeared after we took off the wire plate. 
 
Here is what I have based on the Honeywell installation guide: 
E=Weathertron X2 
Aux=Weathertron W 
Y=Weathertron Y 
G=Weathertron G or F (not sure which one to do) 
O=Weathertron O 
L=Weathertron F 
R=Weathertron R 
B=Weathertron B  (not sure which one to do) 
C=Weathertron B 
 
I'm not sure where the T wire should go or what to do with the grey wire. 
 
Thanks for the help.
     
     
    
    
    
    
    
    
  
   | 
 
    | 
        
                
      
       
        
         
     | 
 
 
	 
	
		 
	 
 
	
	
		
	
	
  
    
    
    
      
                  | 
            
      
              
               New Member 
              
              
              
              
       | 
        | 
      
                
               
                
                  
                      Oct 11, 2007, 07:17 PM
                  
                 
       | 
     
     
    
   | 
 
  
    | 
    
    
       
        
        
        
       
    
    
    
    
                  
        I am replacing a Weathertron with a Honeywell RTH230B and need to know the appropriate wiring configuration?
     
     
    
    
    
    
    
    
  
   | 
 
    | 
        
                
      
       
        
         
     | 
 
 
	 
	
		 
	 
 
	
	
		
	
	
  
    
    
    
      
                  | 
            
      
              
               New Member 
              
              
              
              
       | 
        | 
      
                
               
                
                  
                      Jul 16, 2008, 01:04 PM
                  
                 
       | 
     
     
    
   | 
 
  
    | 
    
    
       
        
        
        
       
    
    
    
    
                  
        Do you have schematic for the Honeywell RTH3100C?
     
     
    
    
    
    
    
    
  
   | 
 
    | 
        
                
      
       
        
         
     | 
 
 
	 
	
		 
	 
 
	
	
		
	
	
  
    
    
    
      
                | 
            
      
              
               Heating & Air Conditioning Expert 
              
              
              
              
       | 
        | 
      
                
               
                
                  
                      Jul 16, 2008, 05:24 PM
                  
                 
       | 
     
     
    
   | 
 
  
    | 
    
    
       
        
        
        
       
    
    
    
    
                  
        
	
		
			
			
				
					  Originally Posted by  freemom06
					
				 
				I am attempting to replace our Weathertron thermostat with a Honeywell RTH3100C. We have a Trane heatpump system.  I am having trouble with the wiring. My wires don't match the 'less common wire designations' in the manual. 
I have the following wires on the Weathertron: 
R-red 
T-brown 
O-orange 
G-green 
Y-yellow 
X2-black 
B-blue 
W-white 
F-Pink 
and a grey wire I don't think was connected to anything-it is not taped off, and we don't remember disconnecting it, it just suddenly appeared after we took off the wire plate. 
 
Here is what I have based on the Honeywell installation guide: 
E=Weathertron X2 
Aux=Weathertron W 
Y=Weathertron Y 
G=Weathertron G or F (not sure which one to do) 
O=Weathertron O 
L=Weathertron F 
R=Weathertron R 
B=Weathertron B  (not sure which one to do) 
C=Weathertron B 
 
I'm not sure where the T wire should go or what to do with the grey wire. 
 
Thanks for the help. 
			
		 
	 
 Here you go on Weathertron/same as Trane
      
     
    
      
      
    
    
    
    
    
    
    
  
   | 
 
    | 
        
                
      
       
        
         
     | 
 
 
	 
	
		 
	 
 
	
	
		
	
	
  
    
    
    
      
                | 
            
      
              
               Heating & Air Conditioning Expert 
              
              
              
              
       | 
        | 
      
                
               
                
                  
                      Jul 16, 2008, 05:26 PM
                  
                 
       | 
     
     
    
   | 
 
  
    | 
    
    
       
        
        
        
       
    
    
    
    
     
    
    
    
    
    
    
  
   | 
 
    | 
        
                
      
       
        
         
     | 
 
 
	 
	
		 
	 
 
	
	
		
	
	
  
    
    
    
      
                  | 
            
      
              
               New Member 
              
              
              
              
       | 
        | 
      
                
               
                
                  
                      Feb 2, 2009, 05:30 PM
                  
                 
       | 
     
     
    
   | 
 
  
    | 
    
    
       
        
        
        
       
    
    
    
    
                  
        I have an old Weathertron thermostat. I just purchased a Honeywell RTH 230B programmable thermostat to replace it. Honeywell have 5 wires RH, RC, W, Y, G. But my old unit utilized 8 wires. G-green, Y-yellow, X2-black, B-blue, U_W-white, O-orange, R-red, T-brown.
     
     
    
    
    
    
    
    
  
   | 
 
    | 
        
                
      
       
        
         
     | 
 
 
	 
	
		 
	 
 
	
	
	
		
	
	
  
    
    
    
      
                  | 
            
      
              
               New Member 
              
              
              
              
       | 
        | 
      
                
               
                
                  
                      Aug 8, 2012, 10:59 AM
                  
                 
       | 
     
     
    
   | 
 
  
    | 
    
    
       
        
        
        
       
    
    
    
    
                  
        I have a old trane mercury thermostat BAYSTAT239A trying to replace it with a honeywell thermostat RTH11B need help with wiring ?
     
     
    
    
    
    
    
    
  
   | 
 
    | 
        
                
      
       
        
         
     | 
 
 
	 
	
		 
	 
 
 
 
 
     
  
   
  
  
   
  
  
  
  
  
  
  
  
  
  
  
  
  
  
    | Question Tools | 
    Search this Question | 
   
  
    | 
    
    
    
     | 
    
    
    
    
    
     | 
    
   
   
   
    Add your answer here.
    
    
 
Check out some similar questions!
Replacing old thermostat with a Honeywell RTH230B
 [ 4 Answers ]
I am replacing my old Honeywell mecury thermostat with a programmable Honeywell RTH230B.  I have two unmarked wires (red & white) connected to the old thermostat.  I know, given my furnace,  that I need to use connections "RH" and "W" on my new thermostat.  What wire, Red/White goes to what...
 
 
Replacing White-Rodgers Thermostat with Honeywell Digital
 [ 7 Answers ]
I am replacing a 13 yr. old White-Rodgers Mechanical thermostat (couldn't find model # on website) with a Honeywell 5-1-1 Digital thermostat. 
 
The wiring was as follows for White-Rodgers: 
 
Green = G 
Yellow = Y 
White = W 
Red = RH jumpered to RC 
 
The Honeywell has terminals for
 
 
Wiring question replacing Honeywell thermostat w/Hunter
 [ 0 Answers ]
I am replacing an old standard Honeywell thermostat (model T8034C) with a Hunter programmable digital model 44110. 
 
I have a 5-wire system. The wires are color coded and the Honeywell labels match the wire colors. Those are: 
 
White, Yellow, Green, Orange, and Red. THe only labels on the...
 
 
Please Help w/Replacing Honeywell Thermostat... 
 [ 3 Answers ]
Hi! 
 
I've just removed my Honeywell Thermostat and am trying to replace it with a Noma programmable tstat... but am having problems with the wiring.  There are 5 wires coming out of the wall - Green, Black, Orange, Red and White, and only 4 posts on the Noma tstat (Green, Red, Yellow and White). ...
 
 
 
View more  questions
Search
 
 |