    Climate zone not at the specified temp in my mayrag refrigerator model mzd2768geb
    My refrigerator is a Maytag model mzd2768geb. It has two temperature controlled drawers. Temperature on these area out of control,i.e. temperature is not maintained as specified at the user manual.
    twinkiedooter's Avatar
    twinkiedooter Posts: 12,172, Reputation: 1054
    Uber Member
     
    #2

    Aug 11, 2011, 01:30 PM

    Do you have independent thermometers inside the drawers so take a proper reading?
    drtom4444's Avatar
    drtom4444 Posts: 3,282, Reputation: 145
    Ultra Member
     
    #3

    Aug 12, 2011, 09:24 AM
    Did you check to see if the coils under the unit were dirty? This is the most common cause because the unit will not bring down the temp enough to keep anything at the right temp when the coils are dirty. Remove the front kick plate and the rear cover (after unplugging unit) and wash out the coils with a spray of water. Clean everything and keep water out of fan motor, but clean the fan blades. Use a good spray cleaner to dissolve grease after washing off one time. Clean out drain pan by sliding it out from front if it comes out like most pans. Then when clean replace rear cover because on many units it is required to route air through the coils. Make sure your inside freezer coils are clear of ice and air can flow. DrTom4444

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

GE Profile refrigerator (Model TFX28PBBB BB) showing "Warm Temp" light [ 0 Answers ]

I have a GE Profile refrigerator (Model TFX28PBBB BB), that at times, is not kicking back into freeze/cool cycle - it runs and then cuts out after the cooling is done and won't come back on (at times) by itself. It is intermittent. I have to play with the Freezer "temp control" to kick it back...

Sears kenmore refrigerator setting of temp. Dial [ 0 Answers ]

My fridge is a model 252.60802400. When we moved in it was already set at this temp. I cannot tell which part of the dial is the point at which you move to cold or colder. We have tried all different directions and it freezes everything or I end up cutting it off instead. The markings are not...

Where to find the model number on my Honeywell Synchron zone valve [ 5 Answers ]

Where to find the model number on my Honeywell Synchron zone valve. I think the Powerhead and/or motor has gone bad. I had no heat in my master BR this morning and after verifying the Thermastat was kicking in I went down and tried to check the valves. This is just 1 zone out of 5 (3 other...

Magic chef refrigerator freezer temp. Control knob [ 1 Answers ]

I have a Magic Chef refrigerator model #RB150TV. The freezer temperature control knob is broken. I have a new knob but I'm not sure how to remove and replace the broken knob. Any help would be appreciated.

2 zone oil heat, 2nd zone runs 1st zone [ 1 Answers ]

Hi, We have a 2 zone oil burner. The 1st zone (upstairs) runs separately and works no problem. The 2nd zone(basment), when we try to run 2nd zone separately , it seems to run zone 1(upstairs) and the baseboard heating upstairs gets hot and heats zone 1 even thought we have the t-stat set low...


View more questions Search