    New water lines
    I am moving a washer and dryer from my basement too the next level of the house. I have a couple of questions/concerns. First:can I safely vent my dryer through the ceiling and a few feet across the insulated attic and out of the eve to the outside? Next: what would be an easy,durable,cost effective choice to run new waterlines off the ends of the old galvanized basement lines (the pipes and threads are in pretty good shape) I was thinking maybe PEX? Or a similar type?
    joypulv's Avatar
    joypulv Posts: 21,591, Reputation: 2941
    current pert
     
    #2

    Mar 7, 2011, 05:41 AM
    The vent will be OK one ceiling up and a few feet out. I think the max is 18'. Be sure the vent has a screen to prevent animals and bugs from getting in! If it only has a flap, make a screen.

    1/2" hot/cold PEX is fine for the supply.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #3

    Mar 7, 2011, 07:58 PM

    Agree with Joypulv, but if you run the dryer vent vertical you'll want to plan on checking it every year for dryer lint build-up, OK?

    If dryer lint builds up in the dryer vent it can not only extend the time it takes to dry your clothes (costing you more money), but it could also be a fire hazard. However, if you check the dryer vent on a yearly basis you should be perfectly safe... ;)

    Good luck!

    Mark
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #4

    Mar 7, 2011, 10:03 PM

    The real question here is, or should be, how are you going to work the drain and drain vent?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Cost to remove/replace galvanized water lines in walls with copper lines. [ 3 Answers ]

The long water lines have been replaced under the house, but not the lines in the wall. What would the cost be for kitchen, 1 full and one 3/4 bath?

Water softener resin clogging water supply lines [ 1 Answers ]

We have a water softener that has a resin filter that has broken numerous times due to surges in water pressure. This time we didn't realize it had broken in time to bypass the softener and avoid getting resin in the lines again. We've already flushed the resin out of the 2 toilets and 2 sinks...

Hot and cold water is somehow backwards in shower but water lines are correct [ 1 Answers ]

I recently installed a new shower valve. I verified (many times) that I installed the hot and cold lines to the correct connections but when I turn the water on to "cold" hot water comes out and when turned to "hot" cold water comes out. I didn't see anything in the manual that indicated it's...

Hot water lines under slab quickly cool the water. [ 2 Answers ]

I'm looking for a good fix for a hot water problem in a 30 year old 20' x 40' condo that is on a slab. The hot water heater is on one end of the unit and the copper pipe runs 40' under the slab to the other end where there is a shower/bathroom. It loops from there back to a second bathroom and on...

Yellow water from cold & hot water lines on city service [ 1 Answers ]

I recently bought a house that is ~30 years old. It has copper pipes. When I first noticed yellow water I flushed my hot water tank, but the water problems persists and it occurs even when I'm running cold water. There is some sediment in the water that looks like the iron content in well water,...


View more questions Search