    Old bryant heat pump
    Need to ghang condenser fan old one has 3 wires black,brown,yellow, new 1 has 5 wires green,black,white,brown,brown with white strip need help on how to install
    ford1962's Avatar
    ford1962 Posts: 2, Reputation: 1
    New Member
     
    #2

    Jan 22, 2011, 02:33 PM
    Black wire goes to curcit bord, white wire goes to capacitor on yellow, brown goes on capacitor marked fan,and brown with white goes on capacitor on where the yellow goes,green is ground I hooked it to the gage where the fan bolted up working good. Hope this will help if any body is having the same trouble

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bryant Heat Pump Capacitor [ 6 Answers ]

The capacitor on my bryant heat pump was bad and I got a new one. 1) the new one is oval and the old one was round. Is it OK if I use this new one or should I try to buy a round one as well? 2) there are three different color wires so when I discoonected the old capacitor, I did not write down...

Wiring diagram for bryant heat pump [ 1 Answers ]

Wiring diagram for bryant heat pump

How do I change the aux heat setting on my bryant a07045 with heat pump [ 1 Answers ]

How do I change the aux heat setting on my bryant a07045 with heat pump

Bryant Heat Pump Making Noise [ 1 Answers ]

I have a Bryant Heat Pump installed 6 years ago - had the coil replaced last year - it has suddenly starting making a chirping noise (sounds a bit like a cricket). The noise is not really constant but happen on and off all day and night. Could this be a sign of a problem or something that might be...

Bryant Heat Pump not cooling [ 4 Answers ]

I noticed the other night that my 14 yr old Bryant heat pump was not cooling when I got home. The fan on the unit was not spinning, but I could hear the unit making a buzz. When I used a stick reach the fan to rotate it, it actually spun up to running speed, but never did cool the air in the...


View more questions Search