    5000 litre rainwater tank won't pump water
    Turn on pump (Goulds WGJ-WGC) attached to water tank, power on & pump on lights come on. Pump runs momentarily & then failure light comes on. Press restart button & pump only runs while this is kept depressed. But no water comes through to toe open tap. Suspect it is not primed but how do you prime it?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Dec 16, 2010, 06:28 AM

    Have you checked the suction line for a blockage? Is this pump in or out of the tank? Let me know, Tom
    mwall8's Avatar
    mwall8 Posts: 2, Reputation: 1
    New Member
     
    #3

    Dec 16, 2010, 01:20 PM
    Many thanks Tom. I suspect you are right. Pump is out of the tank. I am 60Yr old female trying to do own repairs! Will have to get some sort of tool to try & unscrew the hosing (about 17 cm circumference)that runs from tank into the pump.
    Marie53's Avatar
    Marie53 Posts: 1, Reputation: 1
    New Member
     
    #4

    Sep 9, 2012, 03:31 PM
    Hi Tom
    Press restart button & pump only runs while this is kept depressed. But no water comes through to the open tap. The failure button comes on I am a 58 Lady and I try to fix things myself. I will check to see if there is a blockage. Priming the pump was mentioned and how is this done?
    Marie
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #5

    Sep 9, 2012, 07:39 PM
    Marie, if this pump is below the level of the top of the water in the tank, then it won't need priming. It will prime itself. If it is above the tank, it would need to be primed, but then it would also have to have either a footvalve or a checkvalve in order to hold prime. I suspect it is below the water level. That's why Tom suspects the suction line.

    Can you give us a model number for the pump? It should be possible to find a copy of the manual and find out what the failure light indicates when it comes on.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

How to Prime a Water Tank Pump? [ 3 Answers ]

Ok, I have a. O. Smith V60 Aqua Air Water tank with a.O. Smith Pump attached to it. Pump model C48A96B67 1/2 HP Type B I have had a power outage and the person looking after the house while we were away used the water while the power was out, dropping the pressure. Now its not working. I...

Replaced a hot water tank,water is not going to the pressure tank-the pump stays on [ 2 Answers ]

Replaced a hot water tank, turned the pump on and the water is bypassing the pressure tank. The pressure tank will not fill up and the pump remains on and will not shut off. We do get water though but needs to shut off the pump so it will not burn out. Any thoughts? Thank you Any ideas will...

Gravity rainwater tank won't fill cistern [ 3 Answers ]

I have a Fluidmaster (400UK) ballcock in my cistern. I want to use a rainwater tank to fill it just using gravity. The tank's 3 or 4 feet higher but the water won't run in. I've read in this question (https://www.askmehelpdesk.com/plumbing/toilet-cistern-slow-fill-350059.html) details on how to...

Water tank2psi under cut in,draw 2 gal water.pump off, air in tank now at 54psi why? [ 1 Answers ]

Installed new water tank and well pump. Air in water tank is set at 2 psi lower than the cut in for the water pump which is 28 psi- water pump at 30 psi. Draw water 2 gal pump shut off and the psi in the water tank is at 56 psi shouldn't the water read 28 psi? Why 56?


View more questions Search