    Noisy Blower Motor
    I had the 1 hp blower motor on my furnace/air conditioner replaced in December 2005. In the last 2 days, it has gotten extremely loud. It still works, but it sounds like there's an airplane in my basement. Any ideas about what could be going wrong? Is it something that can be fixed or will I need another new motor? The motor came with a 1-year warranty that expired last December. Is that the normal length for a blower motor warranty? I don't want to replace a $500 motor every 18 months!
    esquire1's Avatar
    esquire1 Posts: 2,483, Reputation: 209
    Ultra Member
     
    #2

    Jul 16, 2007, 07:24 AM
    If you replace motor yourself, not difficult to do, you can do it for much less. If the motor itself is noisey, the bearings are bad. You may try oiling at oil port and may buy you a little more time. You may check and make sure the fan has not losened on shaft and is rubbing. Most motors last a very long time. I did get a hold of one in April than went out in May. It did last only 30 days. If you do replace motor, be sure and replace capacitor with the reating on motor at the same time. Good Luck
    robertcfryjr's Avatar
    robertcfryjr Posts: 2, Reputation: 1
    New Member
     
    #3

    Jul 16, 2007, 08:04 AM
    Thanks, Ill see if I can find the oil port -- didn't know there was one -- and also check for a loose fan. The noise could be coming from the fan rubbing or rattling rather than the motor itself. How is fan usually attached to shaft? Could it be something as simple as a loose/missing screw?
    esquire1's Avatar
    esquire1 Posts: 2,483, Reputation: 209
    Ultra Member
     
    #4

    Jul 16, 2007, 08:11 AM
    It will side on the motor shaft. It does have a flat area that will match with flat area on shaft. Then there is a screw to tighten that locks it into place. To oil you will more than likely have to remove it from air handler. Good Luck
    made2last's Avatar
    made2last Posts: 30, Reputation: 2
    Junior Member
     
    #5

    Nov 27, 2007, 08:42 AM
    Comment on esquire1's post
    Might be my problem

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Blower motor [ 2 Answers ]

My blower motor won't stop running . Heat or A/C compresor won't turn on. Tapped on relay still don't shut off. It is a Carrier model#58GS100-2 please help hott in here. Thanks

Blower motor [ 2 Answers ]

How do you install blower motor in a gas furnace?

Noisy blower startup [ 8 Answers ]

In mid-summer I had the blower motor and capacitor replaced in my Comfortmaker RPG II 150,000 BTU natural gas furnace. (The bearing was going out in the motor). This is a direct-drive squirrel cage blower. Since being replaced, it makes a loud 60hz hum startup noise. It varies in pitch as the...

Blower motor [ 1 Answers ]

THere is no air blowing when the heat is on. The furnace does come on but no air blows. If I turn the heat off and manually turn the fan on the air blows. If I leave the fan switch in the on position and turn the heat on the air stops.

Blower Motor [ 1 Answers ]

I have read multiple posts about wiring for blower motors and saw one that almost answered my question. I have an old blower motor that I would like to convert to a shop air filter. I know that it is a multi-speed motor. It has 8 wire connections and are labeled as such: Power cap cap ...


View more questions Search