Ask Experts Questions for FREE Help !
Ask
    joebob222's Avatar
    joebob222 Posts: 2, Reputation: 1
    New Member
     
    #1

    Oct 19, 2009, 05:17 PM
    Baystat 239 to Honeywell 7600D
    Hi all,

    I have scoured the internet and have yet to find a definitive answer to my question I'm about to ask. I have a Trane heatpump (XE800, model TWB718A100B0) that was made in 11/1988. It's got backup electric heat and that's it. Works fine since I moved into my condo and I have recently replaced the old Baystat 239 thermostat with a Honeywell 7600D. Everything works fine, but I'm noticing that every once and a while, it's kicking on the AC while the heat is "on" (the hi/lo pressure lines coming off the inside handler are ice cold). I'm guessing this is the defrost cycle but I've never known it to come on as often as it does now. I've seen this mentioned in a few posts, but my X2 and W on the Baystat were jumpered together (see attached). Well, it's more like the X2 was extended to W as well. Might this have been a way to prevent the defrost cycle from coming on? Not sure why this was done or if I should do the same on my 7600D (ie, jumper AUX and E together even though there is a wire in each now). Any assistance is greatly appreciated. :)

    joebob222's Avatar
    joebob222 Posts: 2, Reputation: 1
    New Member
     
    #2

    Oct 19, 2009, 05:53 PM

    Actually, I think I may have figure it out on my own. There is an actual wiring diagram for a Baystat located here on page 4: http://customer.honeywell.com/techli...0s/69-0392.pdf

    I jumpered E and AUX on my 7600D and it did what I think my old thermostat did (but really didn't pay attention to it); when it runs a defrost cycle (which seems to be frequently), it kicks on the Aux heat (electric) so that the air blowing through isn't cold-'er' due to the defrost running (cool air in, hot air out). As soon as the cycle is done, the Aux goes off and heat pump blows warm air again (I verified by standing by the handler as it did all of this). Might be a good tip for anyone who doesn't want their heatpump running all the time because of defrost cycles. :)

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Wiring for trade from Trane BAYSTAT 240 to Honeywell T8411R [ 10 Answers ]

I have searched and searched and find lots of thing for both of these units, but there is always one thing different. So I will try to explain what I have learned and what I am still confused about. The Honeywell T8411R was given to me, has no instructions and the person that gave it to me said...

Trane Baystat Thermostat to ACE ATX1500E Prg. [ 1 Answers ]

Hey Guys, The old unit is a Baystat 240 and the new unit is an ACE unit Baystat Wiring ACE ATX1500E R G T RH/RC O ...

Baystat 240 to a honeywell rth7500d [ 1 Answers ]

Hi I just purchased a Honeywell rth7500d for my home. I currently have a baystat 240 with a Trane heat pump with strip back up. I have tried to trace the wires and figure witch one goes to the new thermostat but with no luck. My baystat has r t o g y x2 b u w. I drew a diagram of the old wires and...

Replacing a Honeywell T8575D2003 with a Honeywell RTH8500. Having trouble with wires [ 1 Answers ]

I'm replacing a Honeywell T8575D2003 with a Honeywell RTH8500. Didn't think there would be issues, manuals are all straight forward. However when I removed the T8575, the wiring set up did not match what the RTH8500 was expecting. The T8575 has 8 wires connected as follows < 1 ...

Installing Honeywell RTH6300B from an older 7 wire Honeywell. PROBLEMS [ 4 Answers ]

Hello everyone, I am new here. I found this site which trying to troubleshoot my problem. Any assistance would be GREATLY appreciated. Basically I have an older honeywell programmable thermostat with 7 wires attached. They are as follows... C - Black wire L - Blue wire R- Red wire W2 - brown...