    Coil wiring
    When the switch is in the on position is there 12v power to the ignition coil on a four cylinder gas tractor?
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #2

    Jul 20, 2009, 10:37 PM

    In the old days the coil was fed by a resistor in the on position. While cranking, the resistor was bypassed and the coil got full voltage.
    CaptainRich's Avatar
    CaptainRich Posts: 4,492, Reputation: 537
    Cars & Trucks Expert
     
    #3

    Jul 21, 2009, 08:28 AM
    Quote Originally Posted by LeftHandwrench View Post
    When the switch is in the on position is there 12v power to the ignition coil on a four cylinder gas tractor?
    Yes, there should be power at the coil positive terminal.
    The "Negative" terminal is actually the ignition trigger. When it gets a trigger pulse, the coil field collapses and the coil fires.
    One terminal will light a test light with the ignition in the ON position and the other should flash a test light during cranking.
    I hope this helps.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Converting an R22 A-Coil To a Water to Air Coil? [ 8 Answers ]

Converting an R22 A-Coil To a Water to Air Coil A friend of mine has a water to water geothermal unit for heating his home. He wants to use this same unit for cooling the house. Looking at water to air coils the prices are quite steep compared to the standard run of the mill A-Coils. We are...

Ritetemp 8030C Wiring for Climetec Fan Coil Unit [ 5 Answers ]

Hello guys! I've looked all over the net but could not find an answer to my following question. I recently moved in to a condo, which had an old Honeywell thermostat installed. I took it off, there were no markings on the back of the unit, but all six wires coming from the wall were connected...

New Outside Condsing Unit, Bad indoor Coil - Go with Heat Pump or Buy New Coil? [ 7 Answers ]

Hi All, Here is my issue. Recently, our home warranty company paid to replace a 25 year old 7 SEER Borg Warner outside unit, but swore up and down that the indoor Borg Warner Coil would be OK with the new 10 SEER Carrier. We no longer have this home warranty company and they are not standing...

Trane Variable speed w/hot water coil/Ac wiring ? [ 3 Answers ]

I've read many of the previous questions/answers, but haven't found what I need. Low voltage wiring is not my strong suit. My AHU has a hot water coil in it, that I plan to heat with a Voyager water heater. It has an A/C coil, and that works fine. Previous answers have said that I should find a...


View more questions Search