    Hot water runs cold after 1 minute
    Hi hoping someone will be able to help me out with this, I have lived in my flat for 18 months and had no problems with the hot water then 5 weeks ago there was no hot water at all, I was told that I needed a new element and also a new timer I'm on economy 7 so the timer is set to come on during the night ( I'm a council tenant I didn't have to pay for it), so they did the work and left, but when I go to have a bath or do the washing up there is hot water for about a minute then it runs cold, so I got the council back they said I needed a new tank, they have done this and still I have hot water for only about a minute and that's it, really hoping you will be able to give me a couple of suggestions with this
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jul 12, 2009, 01:11 PM
    If The installer soldered a 3/4" male adapter in the cold water inlet on the heater instead of installing brass nipples he could have melted the flange on the plastic dip tube on both heaters allowing the dip tubes to disengage, (see image). This would allow the cold water to mix with the hot water at the top instead of directing it to the bottom where it would be heated by the bottom element. You would draw hot water while allowing cold water to enter at the same time cooling the draw. Exactly what you describe.
    Of course you could have got two bad heaters in a row but that's a stretch.
    My bet's on a faulty installation. Have you checked the timer to be sure it's set correctly? Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

My shower only runs cold water [ 1 Answers ]

I put the taps on under neath bath but the hot was on cold tap and visa versa. I could.nt put them on any other way as the taps would have been facing outside the bath underneath. I then put yhe shower head onto yhe wall in side the shower running off new taps but it only runs the cold

Hot water runs for a minute and then stops [ 3 Answers ]

The hot water in the house for a minute and then stops.I have a mixer tap which I take the top off and blow back the hot water for a minute.The hot water runs again for a minute then stops.There is no banging in the pipes or any noise ,and the hot water system is full

Upstairs Bathroom Sink - Cold water tab runs very warm for first 30 seconds. [ 14 Answers ]

I do not know much about plumbing. I live in the USA. I have a 60 gallon gas water heater. My problem started maybe a month or two ago. In the bathroom sink of my home's second story the cold water in the sink will run very warm (almost hot) for the first 30 seconds. After that it goes back to...

95 civic runs for a minute but. [ 3 Answers ]

All right I have a d16z6 head on a d15b7 block.. it ran fine when I first did the swap until my valve guides took a crap... so $600 later everything is back together and it still won't run.. This is what happens.. After sitting for a while it will start and run fine for about 2 minutes then...