    Anti-siphon valves at different elevations
    (this has been moved by me from another thread here)


    If you have 2 valves in different places at different elevations, is it true that each valve only needs to be higher than the highest sprinkler that it services? I would like to split the supply line and service 2 different areas. Its easier to run electric wire than PVC.
    Name:  sprinkler 1b.png
Views: 1277
Size:  3.5 KB



    Thanks!
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    May 7, 2009, 10:25 PM

    If the anti-siphon valve is lower than sprinkler it will drain water from the sprinkler branch after sprinkler is deactivated. Small overflow will follow from the anti-siphon valve.

    You could solve this problem by installing check valve on sprinkler branch that would hold water in disallowing it to push backwards towards the anti-siphon valve.
    afaroo's Avatar
    afaroo Posts: 4,006, Reputation: 251
    Ultra Member
     
    #3

    May 7, 2009, 11:39 PM

    I agree with Milo to install a check valve and yes it is true that each anti-siphon valve should be higher than the highest sprinkler, Thanks.

    John
    pwd77's Avatar
    pwd77 Posts: 186, Reputation: 3
    Junior Member
     
    #4

    May 8, 2009, 08:14 AM
    Thanks for the responses

    In my diagram, each valve is higher than the sprinkler it serves. The question is whether sprinkler 1 being higher than valve 2 is an issue, or if valve 1 and 2 serve their backflow-prevention independently.

    Here's the deal: I live in cold winter country, but want to keep with the simplicity of anti-siphon valves for backflow prevention. I could run my supply to the highest spot on the land then back to where it goes, which would be a bit of hassle and cost but certainly do-able
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #5

    May 8, 2009, 05:42 PM

    The way it is drawn it is perfectly fine... The back-flow prevention is served by each valve independently. No need to do any modification to this design.
    afaroo's Avatar
    afaroo Posts: 4,006, Reputation: 251
    Ultra Member
     
    #6

    May 8, 2009, 08:16 PM

    Milo I can't rate you it wouldn't let me But I can respond to you this way, you have stated very well no need for me to say any thing.

    Pwd77, your drawing is perfect no need for any thing else, good luck.

    John

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Anti Siphon Hose bib [ 11 Answers ]

I am presently purchasing a home built in 2001. It looks as though I have anti siphon hose bibs, but nothing like I have read being explained by others. This bib seems to have a bronze cap that is added to the bib with holes around the rim where the hose connects. There is a spring and rubber...

Anti-Siphon Valve Installation [ 7 Answers ]

Hello, I am in the process of installing an anti-siphon valve for my home irrigation system. Everyone says it needs to be 6" above the highest sprinkler head. My question is: Does this mean the height of the sprinkler head in the up position or the height of the sprinkler head when the lawn...

Watts anti siphon hose bib (outside) [ 2 Answers ]

Where can I find the anti siphon replacement parts for Watts anti siphon hose bib. The handle has FHB-2 on it but no one in this area has any idea where to get it.

Anti-siphon leake and can't get handle off [ 7 Answers ]

Ok, so I have read up on some of the threads on this topic, but can't seem to find the answer. I have the attached faucet on the outside of the house. When the hose is connected, there is water leaking out of the anti-siphon (at least I think that is what it is - the grey thing on the top). I...


View more questions Search