Ask Experts Questions for FREE Help !
Ask
    alimden's Avatar
    alimden Posts: 1, Reputation: 1
    New Member
     
    #1

    Apr 10, 2009, 09:48 AM
    Symmons Temptrol tub and bath faucet leaking
    I have a Symmons Temptrol tub and bath faucet which is leaking at the handle.
    It is 20 years old and I suspect that the cartridge needs replacing.
    Do I remove the handle first and then the plate which is held by two screws?
    Where is the cartridge located? Is there some literature that will describe a step by step procedure to do this.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Apr 10, 2009, 10:04 AM
    Quote Originally Posted by alimden View Post
    I have a Symmons Temptrol tub and bath faucet which is leaking at the handle.
    It is 20 years old and I suspect that the cartridge needs replacing.
    Do I remove the handle first and then the plate which is held by two screws?
    Where is the cartridge located?. Is there some literature that will describe a step by step procedure to do this.
    I can't give you a "step by step" but here's a cutaway of your faucet. Good luck, Tom
    Attached Images
     
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #3

    Apr 10, 2009, 02:10 PM
    Alimden:

    If you look at Tom's picture you will see part # T-17. This is a bonnet packing nut... here, you will want to remove the handle and tighten that packing nut a 1/4 turn or so and that should stop the leaking at the handle.

    Otherwise, if you wantto replace the cartridge you can see how to access using the pic. Above.

    Let us know if you need more info...

    MARK

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Symmons - Temptrol Diverter [ 22 Answers ]

I have the above diverter in my bathroom. Recently it started to leak from the diverter handle that changes the use from tub to shower. I purchased the Symmons TA-25A Iverter Spindle to replace old. My problem is that I do not know how to remove the old spindle. Can anyone help me with my problem?

Symmons temptrol - no water [ 2 Answers ]

I'm getting nothing but a dribble on hot and cold, tub or shower settings. Was fine until today. Any way to tell if it is the valve or seat? There's nothing else to replace, right? Thanks

SYMMONS Temptrol leaking from diverter [ 1 Answers ]

Symmons sent the replacement seats and tools to repair a leak from the diverter hole that happens only when water is turned on. I replaced the seats, tightening by hand stopping short of cranking them. (I didn't use a torque wrench). Three times I removed them and adjusted them, but the...


View more questions Search