New Member
|
|
Feb 8, 2009, 01:46 PM
|
|
Waterlogged pressure tank
I have a water logged pressure tank, how do I fix this situation, one thur done. Thanks
|
|
 |
Eternal Plumber
|
|
Feb 8, 2009, 03:35 PM
|
|
Is this a galvanized pressure tank, 30 or 40 gallons, or a smaller bladder tank? Tom
|
|
 |
New Member
|
|
Feb 8, 2009, 03:54 PM
|
|
Galvanized pressure tank, 30
|
|
 |
Eternal Plumber
|
|
Feb 8, 2009, 04:02 PM
|
|
I have a water logged pressure tank, how do I fix this situation,
You shut the power off to the pump and drain the pressure tank completely. Once drained you can pressure up the system again. The incoming water will compress the air in the tank and you're back in business. Hope this helps and thank you for rating my answer. Tom
|
|
 |
New Member
|
|
Feb 8, 2009, 04:24 PM
|
|
405-412-0629 can you call
Do I releave the air pressure?
|
|
 |
Eternal Plumber
|
|
Feb 8, 2009, 04:39 PM
|
|
 Originally Posted by wehall31
405-412-0629 can you call
do I releave the air pressure?
My personal calls run 95 cents a minute through Paypal. But save your money. Just follow my directions. All pressure , both water and air, will be relieved when you shut the power off and drain the system. Good luck, Tom
|
|
 |
New Member
|
|
Feb 8, 2009, 04:43 PM
|
|
So don't shut the water off to my home?
|
|
 |
Uber Member
|
|
Feb 8, 2009, 07:18 PM
|
|
Wehall, SB is right on target. When you turn off power to the system (at the breaker), you can drain the tank through an exterior faucet. Once water no longer comes out, the tank will have air in it again. When you turn the power back on, the tank will partially fill with water and the air in the tank will provide the pressure. The problem is this. Something is not working "well" with your system. Most of the systems using galvanized tanks work by allowing the water in the well pipe to drain down to the pump (this is a submerged pump you have?) when the pump turns off. When the pump cuts back on, that air in the well pipe is pumped into the pressure tank. Thus, the tank always has a fresh supply of air. A valve about halfway up the tank bleeds off excess air to prevent the tank from completely filling with air. Plainly, your tank is not being recharged with air. So, the air in the tank is continually absorbed a little at a time into the water, so that as the months pass by, the air eventually is gone. That is where you are now. So you can recharge the tank as SB described, but you will probably face this again in a few months. Does this make sense so far??
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Pressure/bladder tank losing pressure?
[ 11 Answers ]
Well, I have asked some questions about my plumbing before. So I am calling on you guys once again. I have a 52 gallon pressure tank/bladder tank made by wellsaver. I turn the water on and have good pressure for a few minutes then it basically goes dead with no pressure. I recently posted questions...
Bigger pressure tank or increase pressure?
[ 5 Answers ]
I bought a new home and the builder had installed a 20 gal pressure tank. I have a jet pump system where the motor sits directly on the tank itself. I really notice the pump running a bit,but also notice the loss of pressure quickly, especially in the shower.
Now I was thinking of buying a much...
Loss of water pressure w/new pressure tank
[ 8 Answers ]
Hello everyone,
I have a question involving my plumbing. I was having terrible water pressure and I checked the pressure at the pump itself and it was great. Went to the pressure tank and it was trickling. Shut down power to pump and drained system - checked air pressure and it was not...
Waterlogged well
[ 2 Answers ]
Just how do you drain a tank? I've read several items, but... Some say to remove the pressure gauge, but it does not look to me like it unscrews. Some say to hook up a garden hose to the line, some say just open a faucet that is low.
I'm lost. My well comes on when the gauge is on 30, it...
Deep well, pressure tank/switch not building pressure
[ 13 Answers ]
The only way I have water pressure is to leave the power on!
I have replaced the 5 gallon pressure tank (28psi when void of water)/fittings/pressure gauge and tried 3 new 30/50 pressure switches and the problem remains the same.
With the power off, the pressure drops to 0 (not 30). When I...
View more questions