    Hot/cold Switched, what could be wrong?
    I recently had a bathroom remodel and the plumber may have installed the faucet wrong somehow. The handle is labeled on the right for cold and left for hot. But turning it right results in hot and left, cold. The pipes going into the valve assembly are correct. The plumber insists that the problem is with the valve and that it was installed correctly. Can this be right? Can something have been installed backwards or upside down? And what part of the hardware might that be? What will it take to fix the problem?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jan 21, 2009, 07:21 AM
    If this is a Moen faucet the fix is a easy one. Remove the handle and rotate the stem 180 degrees.. Reinstall the handle and see if the cold water's on the right side now. Good luck and thank you for rating my answer. Tom
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #3

    Jan 21, 2009, 07:22 AM
    Hi Groqx:

    COuld be an issue with the cartridge. Is this a MOEN faucet? If so, take handle off and rotate the stem 180 degrees, then install handle again and see if that fixed it.

    If not, let us know the name of the faucet.

    WOW TOM...was writing same thing at the same time as you...;) NEAT!!

    Thanks...

    MARK
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #4

    Jan 21, 2009, 07:23 AM

    I have seen plumbers have hot on right coming out of the wall and cold on left out of the wall, by accident.
    Have seen where they accidentally hooked up Hot water to toilet, Basically just lost track of their pipes.
    If they didn't touch plumbing inside walls, then the valve COULD be the problem.
    I would turn on the Right side(Hot) for a minute and then feel the supply lines coming out of the wall, see which is hot or warm.
    I guess Plumber didn't try 180 degrees out. New plumber?
    Groqx's Avatar
    Groqx Posts: 4, Reputation: 1
    New Member
     
    #5

    Jan 22, 2009, 05:43 AM
    Turns out it is a Delta Faucet. Though inside the assembly there is some sort of gray cylinder to which the handle attaches. Can this cylinder be simply pulled out and turned around 180 degrees like the Moen faucets? Might that fix the problem?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Jan 22, 2009, 06:28 AM
    I would turn on the cold side for a minute and then feel the supply lines coming out of the wall, see which is hot or warm.
    Let me know what you find.
    I like Stratmandos approach. He thinks the plumber may have reversed the hot and cold lines and I'm beginning to myself. Not knowing the model number prevents me from remarking on turning the cartridge 180 degrees. Check the hot and cold npipes first and get back to me with the results. Good luck, Tom
    Groqx's Avatar
    Groqx Posts: 4, Reputation: 1
    New Member
     
    #7

    Jan 30, 2009, 06:49 AM

    I checked the hot and cold lines and they are correct. The hot is coming in on the left and the cold on the right. I am still trying to figure out how to disassemble the front of faucet to take a look at that cartridge/stem assembly.
    iamgrowler's Avatar
    iamgrowler Posts: 1,421, Reputation: 110
    Ultra Member
     
    #8

    Jan 30, 2009, 07:57 AM
    Quote Originally Posted by Groqx View Post
    I checked the hot and cold lines and they are correct. The hot is coming in on the left and the cold on the right. I am still trying to figure out how to disassemble the the front of faucet to take a look at that cartridge/stem assembly.
    Your Plumber likely removed the cartridge when he soldered it to prevent damaging the cartridge and the reinstalled it incorrectly.

    Flipping it around should correct the problem.

    As for the disassembly process, go to Delta's website and download the appropriate .pdf file for your model number.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Switched outlet is always hot [ 3 Answers ]

I tried to split a switched outlet so the top is always hot and the bottom is controlled by the switch. I snapped the brass connector off and wired the neutral (with black tape) to one of the hot leads with a pigtail. The other neutral went to the silver terminal. Turned the circuit back on and...

Switched outlet [ 1 Answers ]

What a great site! I would like to incorporate 2 switched outlets in my rewiring of the living room. I have run 12/2 to the primary tv/stereo outlets; from those I continue to two more outlets and then up to a switch. The easy way to make the bottum of the last 2 outlets controlled by switch would...

Comp not getting switched on [ 3 Answers ]

computer is not getting switched on.the display shows random colours after sometime.what could be the problem?

Heat & A/C are switched - help? [ 1 Answers ]

I wired my new thermostat all by myself and was very proud indeed. It works GREAT - there is only a little problem. If I want heat I must turn the thermostat to "cool" and if I want the a/c then I must turn the thermostat to "heat". I know that there must be two wires switched - but which ones? ...

F1>5 years, switched to H1B [ 3 Answers ]

Hi, I came to USA in August 2000 on an F1 visa, and switched to H1B in Septmeber 2005. I read Atlanta Tax Expert's post about converting from F1 to H1B, but I'm not sure which of the 1040/EZ and 1040NR/EZ I need to fill out since I've been on F1>5 years and on H1B<183 days as of the end of...


View more questions Search