Ask Experts Questions for FREE Help !
Ask
    bobbyc123's Avatar
    bobbyc123 Posts: 3, Reputation: 1
    New Member
     
    #1

    Jan 3, 2009, 07:56 AM
    Temptrol bath and shower valve
    Valve leaks when I move the bath to shower knob around. The leak comes from only that area. Can I fix this without replacing the whole valve.
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    Jan 3, 2009, 08:27 AM

    Yes, you can fix any leaking faucet w/o replacing entire body valve. What type/brand/kind of faucet do you have ?
    bobbyc123's Avatar
    bobbyc123 Posts: 3, Reputation: 1
    New Member
     
    #3

    Jan 3, 2009, 08:49 AM

    Mio, it is a symmons temptrol model a is all I can read off it.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Jan 3, 2009, 09:13 AM
    Bobbyc123...

    Are you saying that the valve leaks from the trim area when you SLIDE the diverter handle from tub to shower? Let me know...

    If so, then they make a diverter replacement spindle... be sure to pick up the WHITE one for tub/shower valve (see picture) or the BLACK diverter spindle if shower valve only. They sell these at all home improvement stores.

    You will also need to pick up a 5/16" x 3" lag screw and a 5/16" allen wrench and some plumber's grease. Here, you remove the valve trim and then you use the allen wrench to remove the brass nut at spindle and then screw the lag bolt into the spindle... then you YANK on the lag screw to remove the spindle. Then just need to grease the o-ring a bit, slide into place (push hard to set spindle deep), and re-install brass nut and valve trim.

    Let me know if this makes sense or if I'm way off...

    MARK
    Attached Images
     

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Symmons Temptrol Shower Valve - Cold Water Only [ 2 Answers ]

I have several 10 year old Symmons Temptrol Model A shower units. One has recently stopped all hot water. A second is warm at best. I was told by a friend (not plumber) that I need to replace the mixer valve or the part that stopps scolding. The reason being is the part wears out and defaults to...

Symmons temptrol valve on shower/tub [ 5 Answers ]

I can only get hot water from this brand new valve. Yhe only way to get cooler water is to reduce the valve to a point where I get very low flow. Increasing the flow to a satisfactory flow only gives hot water. The water coming in is at 130 degrees F. I can not change the temp of the water coming...

Temptrol shower valve leaking from diverter [ 2 Answers ]

I have a 1985 vintage Temptrol shower valve, model A, that is leaking from diverter. When I turn the handle I get a burst of water from the hole where the diverter handle plugs in. I have a parts breakdown list but it looks like a newer model. Can mine be repaired? Thanks

Symmons Temptrol Shower/Tub Handle - [ 1 Answers ]

I printed off the internet the part breakdwon to my tub/shower one-dial Symmons Temtrol kit as I am trying to stop a slow leak out oif the tub faucet. I removed the screw and cap - and I can't get the handle off - is it hyst suppoosed to pull off once the screw is removed? That is how the...


View more questions Search