Fuse keeps blowin out no heat
6 year old goodman
Forced air
Slit system
I hear heat click over on thermostat but nothing starts up 1 the fuse is blown
2 no red light on in the furnace indication powerTry to replace fuse keeps blowin outnotnot really handy on tight budget what am I up against money wise if I get someone to fix ?
|
|
 |
Heating & Air Conditioning Expert
|
|
Jan 2, 2009, 04:38 PM
|
|
Without knowing where the short circuit is it is impossible to tell how much the labor and parts will be. To get a more accurate estimate I suggest you contact a local repair shop for a estimate.
|
|
 |
Ultra Member
|
|
Jan 2, 2009, 04:41 PM
|
|
What fuse is blowing? Is it a power supply fuse, or a small automotive-type fuse on the circuit board?
|
|
 |
New Member
|
|
Jan 2, 2009, 04:55 PM
|
|
Automotive fuse kc hvac1000 short circuit would be inside heating unit itself ?
|
|
 |
Ultra Member
|
|
Jan 2, 2009, 05:00 PM
|
|
This will require some trial-and-error without a multimeter. How many extra fuses do you have?:o
|
|
 |
New Member
|
|
Jan 2, 2009, 05:04 PM
|
|
Soon as I put fuse in blows right away, other day flathead screwdriver kicked it on when I put it where fuse went but not today
|
|
 |
New Member
|
|
Jan 2, 2009, 05:06 PM
|
|
4 more fuses
|
|
 |
Ultra Member
|
|
Jan 2, 2009, 05:08 PM
|
|
If you see a square multi-pin connector plug near the center of the circuit board, disconnect it and then try another fuse. Does it still blow with connector unplugged?
|
|
 |
New Member
|
|
Jan 2, 2009, 05:22 PM
|
|
I'm sorry I don't see a multi pin connector in center of circuit board ?
|
|
 |
Heating & Air Conditioning Expert
|
|
Jan 2, 2009, 05:26 PM
|
|
First start by eliminating the thermostat from the equasion. Label and disconnect all thermostat wiring on the inside of the furnace. The labeling is important because once fixed you will need to hook them back up.
With the wires disconnected replace the fuse and repower the furnace. If the fuse still blows post back for further instructions.
|
|
 |
Ultra Member
|
|
Jan 2, 2009, 07:58 PM
|
|
Had you done some kind of work on the furnace and if so was the unit working before you worked on it.
If so let me know what you did and I will try to help you.
|
|
 |
Ultra Member
|
|
Jan 2, 2009, 08:33 PM
|
|
Maybe he gave up...
|
|
 |
New Member
|
|
Jan 2, 2009, 10:02 PM
|
|
Sorry I'm not capable of disconnecting thermo wires in furnace fraid to scrrew it up I had the
Transformer changed and heat worked for 3 days then it blew fuse and crapped out ?
|
|
 |
Ultra Member
|
|
Jan 2, 2009, 10:25 PM
|
|
Unfortunately, professional service may be unavoidable unless you are satisfied to keep feeding parts to the machine. Sometimes, the sooner you bite the bullet, the fewer the teeth you break.
|
|
 |
Ultra Member
|
|
Jan 3, 2009, 12:54 AM
|
|
 Originally Posted by romdog55
6 year old goodman
forced air
slit system
I hear heat click over on thermostat but nothing starts up 1 the fuse is blown
2 no red light on in the furnace indication powerTry to replace fuse keeps blowin outnotnot really handy on tight budget what am i up against money wise if i get someone to fix ?
I had a shorted out contacter do this once,, like to never found it,disconnect all the wiring to heat pump,, low and high voltage see if it continues to blow furnace fuse
|
|
 |
Senior Member
|
|
Jan 3, 2009, 10:53 AM
|
|
I had a similar problem with a couple of Goodman condensing units. The coil on the contacter shorted and blew the mini fuse.
Not sure if romdog realizes we are HVAC/R professionals lol.
|
|
 |
New Member
|
|
Jan 3, 2009, 11:26 AM
|
|
I'm sorry mark I appreciate your help do u know what repair would cost
|
|
 |
Ultra Member
|
|
Jan 3, 2009, 11:40 AM
|
|
Cost of a service call plus 30 --40 bucks,, maybe
|
|
 |
Senior Member
|
|
Jan 3, 2009, 12:00 PM
|
|
 Originally Posted by romdog55
im sorry mark i appreciate your help do u know what repair would cost
It's way too difficult to pin down a price and to honest it would be unfair to both yourself and your service company. I do not like to give out numbers in a forum like this unless it is obvious someone is getting ripped off. In fact, other similar forums do not allow it at all. Bottom line is that we do not know for certain that this is your problem since you are not willing to do what was suggested. It could be something else all together.
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Need Fuse for Trane XE900 Weathertorn Heat Pump
[ 3 Answers ]
Were can I get a 300 volt fuse for the Trane XE900? It's the small metal and glass one, looks like an automotive fuse.
The following places don't have one;
The Home Depot
Orchard Supply
Lowe's
Ace Hardware
True Value
Gas Furnace, No spark, no heat--fuse or transformer?
[ 3 Answers ]
Hi
My thermostat was accidentally knocked-off the wall--it didn't work and so I purchased a new thermostat (a simple digital thermostat, non-programmable). This too did not work. It's a 2-wire system hooked-up to a simple Rh/W config. It was set on Heat and Fan "On" and at a normal 70 F....
93 honda vx acg fuse keeps blowin
[ 1 Answers ]
Acg fuse keeps blowing out when key is turned on. HELP!
What is the acg fuse connected to and how can I prevent this?
Heat Pump and burned fuse - Need HELP?
[ 2 Answers ]
I am having a problem with our heat pump. The last 2 days we have noticed a burning smell downstairs and were trying to locate where it was coming from. Narrowed it down to the heat hump. Vacuumed the unit out and replaced the filter yesterday. This morning had the same problem. Seems to happen...
View more questions