Sewage smell
I have a large sewage ejector pump in the basement. The sewage from the house collects in the large sump pit and gets pumped out into the sewer system. There is always some dirty water at the bottom and it has sewage in it. I would like to get rid of the odor. What can I do. Thank you for any help
|
|
 |
Eternal Plumber
|
|
Oct 22, 2008, 05:53 AM
|
|
the sewage from the house collects in the large sump pit and gets pumped out into the sewer system. There is always some dirty water at the bottom and it has sewage in it.
Are you saying that you have a open sump pit that collects the sewerage? Let me know, Tom
|
|
 |
New Member
|
|
Oct 23, 2008, 04:06 PM
|
|
It is not open sir, but it is not air tight
|
|
 |
Plumbing Expert
|
|
Oct 23, 2008, 04:11 PM
|
|
If it is not air tight then you will smell sewer gas. It should be completely air tight, and vented properly. Do you have one or two pipes coming from the top of the pit? If you have two, then one is pump discharge and the other is a vent. If this is the case I would seal all openings in the pit cover.
|
|
 |
Eternal Plumber
|
|
Oct 26, 2008, 03:56 PM
|
|
 Originally Posted by blizzardm17
it is not open sir, but it is not air tight
When your fixtures drain into the pit it sets up a pressure inside the pit that's taken away by the dedicated pit vent that pushes it out, That's where your sewer gas comes from if the pit's not sealed. As the pit empties the pit vent reverses itself and pulls air into the pit. This is why the pit vent MUST be separate form the house vents. Seal the pit and your smell goes away. Good luck, Tom
|
|
 |
New Member
|
|
Oct 26, 2008, 04:14 PM
|
|
Thank you both for your help. There is a separate vent for the pit but at the spot it goes outside it is bent down aiming at the ground, do you think it matters and should I turn it upward? I will seal the pit because the smells are the worst when the big pumps go off and shoot the sewage into the street
|
|
 |
Plumbing Expert
|
|
Oct 27, 2008, 06:15 PM
|
|
Yes turn it it upwards, or straight out, definitely shouldn't be turned down. However, I still believe the problem is in the sealing of the pit.
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Sewage smell
[ 1 Answers ]
I have an odd problem in an old house I just bought. The big problem is that just after doing laundry, and only then, there is a strong sewage smell. The second, and probably connected problem, is that when the washer drains, there is a backup in the sink next to the laundry room. My guess is...
Sewage smell
[ 3 Answers ]
Hi,
My downstairs bathtub is emitting a horrible sewer smell and I've poured bleach and boiling hot water down the drains but it still smells. The smell is also coming out of the drain from my laundry area in the garage (I think the pipes are connected.) Do I need to have a plumber come out...
Sewage smell
[ 1 Answers ]
Hello,
About a week ago the pump for my septic tank broke. I replaced the pump
And everything is working fine now. My problem is that some sewage backed up into my downstairs washroom onto an old cement floor. I have noticed a strong odor in the basement and coming up through the air vents. I...
Sewage smell
[ 1 Answers ]
I have a one year old home which this past summer, I was getting a sewage smell. At first is was only happening on a windy day. I'm on septic system, my floor drains in basement are always full with water. I was getting the smell in my sons room through the return air grill.. After I figured...
Sewage Smell
[ 6 Answers ]
We have sewage smell that seems to be coming from the stack pipe the runs from the basement to the roof. Here is some back ground on the setup, now I'm not a plumber so bare with me. This is a older two story house, the vent pipe is cast iron and runs from the sewer pipe that goes out the...
View more questions
Search
|