    I am installing a new tub trap for a jetted tub I am installing. I have a 2x8 vertical ledger right where the drain needs to be. So, my question is:

    If I install a trap without having the pipe go vertically down from the drain first, will this disrupt the flow of water to the point where I won't have free-flowing water. I was planning on putting two ninety degree PVC joints that then attach to the trap. But is is not straight down into the trap from the drain. Is this against code?

    Thank you.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Oct 2, 2008, 12:52 PM
    How much of a offset do you have to have? Installing a "dogleg" with two 90's is never a good idea in drainage. It slows the flow down and is a dandy place for clogs to hang out. 45's would be much better.
    I have a 2x8 vertical ledger right where the drain needs to be.
    Or, you could simply cut the 2 X 8 and head it off. Good luck, Tom
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #3

    Oct 2, 2008, 06:44 PM

    Tom gave you very good answer... There is always way to run it through framing. Can you post a photo of the trap area ?
    bellilulu's Avatar
    bellilulu Posts: 3, Reputation: 1
    New Member
     
    #4

    Oct 3, 2008, 09:46 AM
    I am not sure how to attach an image but the problem is simple. I just don't want compromise the load bearing of the floor by cutting through a 2 x 8. This is a 42" wide tub and is estimated at around 800 - 900 lbs max. I would pretty-much eat through the entire board trying to make room for the trap. To give you a better idea of the area, the 2 x 8 sits on top of an outside wall because there is an overhang on the 2nd story. The drain center is just inside that wall and directly over the 2 x 8 ledger. It couldn't have been more of a hastle.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #5

    Oct 3, 2008, 09:58 AM
    Willa offset tub waste and overflow work for you? (see image) Having a picture would help us a lot. Let me know! Tom
    bellilulu's Avatar
    bellilulu Posts: 3, Reputation: 1
    New Member
     
    #6

    Oct 3, 2008, 10:35 AM
    Yes, that is something that will work, thank you.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Double trap OK? Rough in piping + tub trap [ 10 Answers ]

The way the 2" rough in went we ended up with a trap of sorts then a pipe to where the tub trap will be. Not completed yet. Just wondering if a tub trap and a trap made with the rough in piping will cause some sort of problem. The rough in trap was made off a 4x4x2 wye. Would that be adequate...

Running Trap vs. P Trap? [ 1 Answers ]

I am currently in the process of chaning a garden tub into a custom tiled shower. The drain location needed to be moved. I have the slab cut and I have excavated to show all the plumbing. (Was not as hard as I thought it would be) My question is this: The current P trap location is 24 inches...

Changing out PVC P-trap to decorative P-trap [ 10 Answers ]

My husband and I are in the process of changing out a vanity in our guest bathroom and I have a few questions. We removed the old vanity and had to cut the old p-trap off with a hack saw. We are replacing with an open vanity so now the pipes will be exposed. I want to tile half way up the wall,...

Replace P-trap with drum trap--good idea? [ 3 Answers ]

Hi, I have a large crack in a cast iron waste line. The line at that point serves just the kitchen sink and is vented to the roof. The first plumber I called wants to disconnect the P-trap, install a drum trap, drill through the cabinet and floor, and connect to the waste line down below the crack....

P-trap GAP - p-trap too low to meet sink drain extension [ 13 Answers ]

I just took an old crane drexel sink off the wall and replaced it for the time being ( I want to fix the older sink) with a cheap vanity/sink set. All that was easy enough, but now to my chagrin I can't finish the job. The p trap is too low, the extension pipe from the sink doesn't go all...


View more questions Search