    Plumbing-dielectrical fittings on galv pipe
    Do I need a dielectrical fitting on galvanize pipe to a brass gate valve?
    Thanks
    Roxy
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Sep 5, 2008, 08:22 AM
    Yes, if this is a water line, no if its gas.
    roxypaws's Avatar
    roxypaws Posts: 3, Reputation: 1
    New Member
     
    #3

    Sep 5, 2008, 08:31 AM
    It is a 20 year old galv water line and this is third gate valve that I replaced - the homedepot guy said that I need a dielectrical fitting to Correct the corrosion. My little pendalum in side the gate valve has been eaten away!!
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #4

    Sep 5, 2008, 08:33 AM
    That fitting will prevent electrolysis from corroding your pipes. All dissimilar metals must be isolated from each other in a water system. Dissimilar does not mean totally different. Brass and copper can not touch galvanized, they are dissimilar. Copper and brass can touch each other, they may not be the same but they are similar.
    roxypaws's Avatar
    roxypaws Posts: 3, Reputation: 1
    New Member
     
    #5

    Sep 5, 2008, 08:53 AM
    Thanks! Roxy
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #6

    Sep 5, 2008, 08:58 AM
    Hey Roxy:

    Here is a picture of the fitting you are looking for... let us know if need more information...

    MARK
    Attached Images
     
    albinfla's Avatar
    albinfla Posts: 310, Reputation: 35
    Full Member
     
    #7

    Sep 5, 2008, 09:59 AM
    These experts are absolutely correct. If using the dielectric fittings is too much trouble, you can also use pvc, or stainless steel valves. I have done both.
    Al
    truck 41's Avatar
    truck 41 Posts: 221, Reputation: 21
    Full Member
     
    #8

    Sep 5, 2008, 11:33 PM
    I would stay away from the gate valve and use a ballvalve.:D ----Zeke---

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Connecting pvc pipe and fittings [ 1 Answers ]

Procedures for connecting pipe to fittings

Glueless and solderless plumbing fittings [ 4 Answers ]

I have heard that there is new fittings out that don't require any glue or soldering. Is this true?

1 1/4 inch fittings won't fit 1 1/4 pipe [ 1 Answers ]

The pvc nipple on the intake of my shallow well pump was leaking. I cut the 1 1/4 inch pipe and was going to couple in a new nipple. The coupling would not fit the old pipe. It is white 1 1/4 " and so is my replacement pipe. I showed it to three different hardware stores and none of them could...

Removing galv fitting from cast iron pipe [ 4 Answers ]

What is the best way to remove a threaded stuck lead fitting from a cast iron section? The fitting was from a lead sink drain pipe and it connected to the cast pipe at the toilet elbow. I tried a pipe wrench and a hammer to try to budge it but no go. I want to thread new PVC into the section of...


View more questions Search