    Trane XE1000- won't cool, blows,
    Manufactured in 2000, 40 rated fuse outside next to unit, 45 at main power box, won't cool, hear light buzz or hum from external unit, I can replace anything needs replacing on the outside, on a budget, need to know what to trouble shoot, seems fuses are good. :mad:
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jun 25, 2008, 03:47 AM
    Check the fuses with a meter or replace with known good ones.

    The contactor in the unit is probably the buzz you hear so the 24 volt low voltage control circuit is working.

    Check inside of the outside unit for loose wires and check the compressor terminals to be sure one did not burn off or come loose.

    Just or starters.
    muppytime's Avatar
    muppytime Posts: 2, Reputation: 1
    New Member
     
    #3

    Jun 25, 2008, 10:29 AM
    Quote Originally Posted by muppytime
    Manufactured in 2000, 40 rated fuse outside next to unit, 45 at main power box, wont cool, hear light buzz or hum from external unit, I can replace anything needs replacing on the outside, on a budget, need to know what to trouble shoot, seems fuses are good. :mad:
    I had someone come and take a look, it was a capacitor
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #4

    Jun 25, 2008, 10:41 AM
    Good deal

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Furnace blows cool air [ 2 Answers ]

I have a new American Standard energy efficient 2-stage furnace installed. When it kicks on the air feels cool. The house does eventually warm up to the correct temperature but I have to keep it at a higher temperature to feel warm. Do the new energy efficient furnaces kick out cooler air? My...

Carrier Heater won't shut off! Blows only cool air. Heat won't work! [ 1 Answers ]

Does anyone know what I can do? My carrier heater is only 2 years old. As of yesterday the heater unit wouldn't shut off and when I turn the heat up it just keeps blowing cool air. I heard I can trip a breaker switch. Is that the electrical switch in the garage or on the heater itself? Please let...

Wiring Thermostat Honeywell 8320U to Furnace-heat pump Trane XE78+XE1000 Combo [ 4 Answers ]

Hello, I have the following systems, each set is functional and individually controlled by two separate Trane Weathertron BAYSTAT240 thermostats. Set 1: Trane Weathertron: BAYSTAT240 Heat side Trane XE78: TUD080C936A1 (Date: 02/1993) Cooling side Trane XE78: TXCO36C4HPB0 (date H06) Heat...

My furnace only blows cool air [ 2 Answers ]

I just bought a townhouse, and last weekend the furnace worked fine. Now, all that I get out of the registers is cool air. The furnace ran almost all night, but no warm air at all. What might the problem be?

Furnace blows cool air [ 1 Answers ]

My furnace is a bryant model-cacf030aza 5yrs old, natural gas,forced air the problem is that the air coming out of vents is cool air , we have central air, but we made sure that the thermostat was set to heat. In the furnace we do not see any fire at all. It is on and it blows but the air is cool...


View more questions Search