Ask Experts Questions for FREE Help !
Ask
    TMONTES's Avatar
    TMONTES Posts: 2, Reputation: 1
    New Member
     
    #1

    May 27, 2008, 02:52 PM
    Hot water heater
    I have an electric hot water heater that I think is broken. There is no hot water coming out of the faucets. We have opned up the drain valve and there is no hot water there. That should we do next?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    May 27, 2008, 03:04 PM
    First check the breaker box for a thrown breaker. Next open up the top inspection plate and check the red reset button on the top thermostat. If everything's OK there and you have power to the heater click on back. But first make sure the heater has power going to it. Good luck and let me know, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

New hot water heater installed, but no hot water pressure. Plenty of cold water? [ 11 Answers ]

Hi, I own a small plumbing service and have a problem I've never encountered before. I installed a new top vented gas water heater for a customer. Turned the main back on, bled air out of the lines, etc. Problem is there is no hot water pressure throughout the house. Cold water pressure is fine....

Need help deciding between a tank or tankless water heater [ 19 Answers ]

Which one saves me money; the tankless water heater or conventional tank water heater? :confused:

Surging water pressure & leaking water heater relief valve [ 19 Answers ]

Just recently the pressure of our water in the house surges when we turn a faucet on, and the city water company verified that our pressure in the house when we open a faucet is higher than the pressure in the lines in the street, and after the water runs is at a normal pressure (meaning their...

Connecting a tankless water heater and separate hot water heater [ 6 Answers ]

What I have is this. An oil fired boiler that generates hot water for my house baseboard heating system. Contained within the boiler is a tankless heater that is heated by way of the firebox in the boiler. The tankless heater is used only for domestic hot water. It has a separate CW supply to the...

Reduced water pressure after installation of new water heater (entire house) [ 6 Answers ]

Hello, We just had a new water heater installed yesterday and the water pressure seems to be reduced (probably 85-90%) of the prior level, through out the entire house. Our old water heater started to leak yesterday AM, had the new one installed that afternoon (40 gallon, 9 year wty, gas: GE...